24
11.2 Brivis Programmable and Brivis Manual Thermostat Installation
Brivis Programmable and Brivis Manual Thermostats can be wired directly to a StarPro heater.
Wiring the Brivis Programmable Thermostat (Part No. B019873)
• Run the appropriate wiring from the heater to the Thermostat.
• Remove the backing plate from the Thermostat. Draw the wires from the wall cavity and feed them through the
centre opening of the backing plate. Then mount the backing plate on the wall before making the wiring
connections.
• Connect terminals R and W on the heater to terminals R and W on the Thermostat.
• For fan only operation - Connect terminal G on the heater to terminal G at the Thermostat. This will allow for
fan only operation to circulate air through the house.
• Insert batteries and mount Thermostat onto the backing plate.
• Refer to the Installation Guide and Operating Manual supplied with the Brivis Programmable Thermostat.
Diagram 23.
Brivis Programmable
Thermostat
StarPro heater
Note:
For a BX5 unit connect the thermostat wiring at the terminal block, refer Diagram 20.
Wiring the Brivis Manual Thermostat (Part No. B022880)
• For manual Thermostats remove the front cover and mount the Thermostat in a suitable position, following the
instructions supplied with the control. Ensure the batteries are correctly installed.
• Make wiring connections (see diagram), then mount level on the wall before replacing the front cover.
• Connect terminals R and W at the heater to terminals A and B on the Thermostat.
• For fan only operation - Wire a switch in circuit between the R and G terminals at the heater.
• Refer to the Installation Guide supplied with the Manual Thermostat.
W
R
324702 CAAB024953 StarPro Installers Heat issue D.indd 27