background image

TABLA DE CONTENIDOS

Reglas De Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
Conozca Su Generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Ensamblaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Funcionamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-24
Especificaciones Del Producto / Mantenimiento . . . . . . . . . . . . 25
Almacenamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Notas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Diagnosticos De Averías . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Esquemático / Digrama Eléctrico . . . . . . . . . . . . . . . . . . . . . 12-13
Piezas De Recambio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-17
Garantia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

DESCRIPCIÓN DEL EQUIPO

Lea este manual de manera cuidadosa y familiarícese con
su generador. Conozca sus usos, sus limitaciones y
cualquier peligro relacionado con el mismo.

Este generador funciona en base a un motor, de campo eléctrico
giratorio y de corriente alterna (AC). Fue diseñado con la finalidad
de proveer energía eléctrica para luces eléctricas, aparatos,
herramientas compatibles y cargas de motor. El campo giratorio
del generador funciona a una velocidad de 3,6000 rpm usando un
motor con un solo cilindro.

¡PRECAUCIÓN!

No sobrepase la capacidad de vataje y

amperaje del generador. Revise "No Sobrecargue el Generador" en
la página 24.

Se ha hecho cada esfuerzo posible para asegurarse que la
información que aparece en este manual es exacta y se encuentra
actualizada. Sin embargo, Briggs & Stratton se reserva el derecho a
cambiar, alterar o de otra manera mejorar, el producto y este
documento en cualquier momento, sin previo aviso.

El Sistema de Control de Emisiones para este generador está
garantizado para juegos estándares por la Agencia de Protección
Ambiental. Para mayor información acerca de la garantía, consulte
con el manual del propietario del motor.

INSTRUCCIONES DE SEGURIDAD

El símbolo de alerta de seguridad (

) es usado con una palabra

(PELIGRO, ADVERTENCIA, PRECAUCIÓN), un mensaje por
escrito o una ilustración, para alertarlo acerca de cualquier
situación de peligro que pueda existir. PELIGRO indica un riesgo
el cual, si no se evita, causará la muerte o una herida grave.
ADVERTENCIA indica un riesgo el cual, si no se evita, puede
causar la muerte o una herida grave. PRECAUCIÓN indica un
riesgo, el cual, si no se evita, puede causar heridas menores o
moderadas. PRECAUCIÓN, cuando se usa sin el símbolo de
alerta, indica una situación que podría resultar en el daño del
equipo. Siga los mensajes de seguridad para evitar o reducir los
riesgos de heridas e inclusive la muerte.

BSP 3200 Generador

18

El escape del motor de este producto contiene

elementos químicos reconocidos en el Estado de

California por producir cáncer, defectos de nacimiento u

otros daños de tipo reproductivo.

ADVERTENCIA

• Opere el generador SOLAMENTE al aire libre.

• Mantenga al menos 2 pies de espacio libre alrededor del

generador, para la adecuada ventilación.

• No opere el generador dentro de un edificio o lugar cerrado,

incluyendo el compartimiento del generador en un vehículo
recreativo o RV.

Al generador funcionar, se produce monóxido de
carbono, un gas inodoro y venenoso.

El respirar el monóxido de carbono, producirá
náusea, desmayo o la muerte.

PELIGRO

• Cuando use un generador como poder de energía auxiliar, notifique a

la compañía de utilidades. Use el equipo de transferencia aprobado
para aislar el generador de otra utilidad eléctrica.

• Use un interruptor para la falla del circuito de tierra (GFCI) en

cualquier área bastante húmeda o que sea altamente conductiva, tales
como terrazas de metal o trabajo hecho con acero.

• No toque los alambres pelados o receptáculos.

• No use un generador con cables eléctricos que estén malgastados,

rotos, pelados o dañados de cualquier forma.

• No opere el generador bajo la lluvia.

• No maneje el generador o cables eléctricos mientras esté parado en

agua, descalzo o cuando las manos y los pies estén mojados.

• No permita que personas descalificadas o niños operen o sirvan al

generador.

Los generadores producen un voltaje muy poderoso.
Si no aísla el generador de utilidades de energía,
puede hacer que los trabajadores de electricidad
sufran heridas graves e inclusive la muerte, debido a
la retroalimentación de la energía eléctrica.

PELIGRO

• Los Códigos Nacionales para la Electricidad, requieren que los

generadores estén haciendo tierra de una manera aprobada. Llame a
un electricista para conocer los requisitos locales para hacer tierra.

Si no hace tierra apropiadamente con un generador,
puede hacer que ocurra un electrocutamiento,
especialmente si el generador se equipa con un juego
de la rueda.

PELIGRO

Summary of Contents for 1773-0

Page 1: ...dealer for further information Preguntas La ayuda es justa un momento lejos Encuentre su Briggs y Stratton distribuidor en nuestro mapa del localizador de distribuidor en www briggspowerproducts com...

Page 2: ...or or moderate injury CAUTION when used without the alert symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The e...

Page 3: ...ge to generator Excessively low speeds impose a heavy load CAUTION See Don t Overload Your Generator on page 8 Start generator and let engine stabilize before connecting electrical loads Connect elect...

Page 4: ...e is provided with a push to reset circuit breaker to protect the generator against electrical overload Fuel Tank Capacity of one U S gallon Grounding Wing Nut Provides a tie point for connecting the...

Page 5: ...n the generator Do Not use premium gasoline Do Not mix oil with gasoline Do Not overfill the gas tank Clean area around fuel fill cap remove cap Slowly add unleaded regular gasoline to fuel tank Be ca...

Page 6: ...builds up in ungrounded devices OPERATING THE GENERATOR CAUTION Never start or stop unit with electrical loads connected AND with the connected devices turned ON Starting the Engine Disconnect all ele...

Page 7: ...se each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volts at 20 Amps or greater...

Page 8: ...output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional...

Page 9: ...sulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings To Clean the Generator Use a damp cloth to wipe exterior surface...

Page 10: ...soline 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Overchoking 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compres...

Page 11: ...BSP 3200 Generator 11 NOTES...

Page 12: ...BSP 3200 Generator 12 SCHEMATIC...

Page 13: ...BSP 3200 Generator 13 WIRING DIAGRAM...

Page 14: ...BSP 3200 Generator 14 EXPLODED VIEW MAIN UNIT...

Page 15: ...95003AGS 1 ASSY Control Panel see page 16 17 74908GS 4 SCREW 18 191459GS 1 DECAL Control Panel 19 91825GS 1 RECTIFIER Brush Bridge 20 66849GS 2 SCREW 21 86494GS 1 SCREW Wing 22 26850GS 2 WASHER Shakep...

Page 16: ...rt Qty Description 1 95600 1 COVER Control Panel 2 75475 4 SCREW 3 94396B 1 BREAKER Circuit 4 94396A 1 BREAKER Circuit 5 23365 4 WASHER Shakeproof 6 68759 1 OUTLET 120 V 20 A Duplex 7 38150 4 WASHER 8...

Page 17: ...BSP 3200 Generator 17 NOTES...

Page 18: ...ta indica una situaci n que podr a resultar en el da o del equipo Siga los mensajes de seguridad para evitar o reducir los riesgos de heridas e inclusive la muerte BSP 3200 Generador 18 El escape del...

Page 19: ...o de la bater a contiene cido y es extremadamente c ustico El contacto con el fluido de la bater a puede causar quemaduras qu micas severas PELIGRO No toque las superficies calientes Permita que el eq...

Page 20: ...aparatos especiales e iluminaci n el ctrica de 120 Voltios AC a 20 Amperios monof sica de 60 Hz Tomacorriente con Dispositivo de Seguridad de 120 240 Voltios 20 Amperios Puede ser utilizado para sumi...

Page 21: ...premium No mezcle aceite con gasolina Limpie el rea alrededor del llenado de gasolina retire la tapa Llene lentamente el tanque con gasolina sin contenido de plomo Sea cuidadoso de no llenar excesivam...

Page 22: ...a encienda o pare el motor con las cargas el ctricas conectadas a los recept culosY con los aparatos conectados ENCENDIDOS Encienda el Motor Desconecte todas las cargas el ctricas del generador Use la...

Page 23: ...e sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes de 20 Amperios Use los juegos de cables que son calificados para cargas de 125 Voltios AC a 20 Amperios o mayores 120...

Page 24: ...rato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga...

Page 25: ...eventualmente la resistencia del aislamiento de estos devanados Para Limpiar el Generador Utilice un trapo h medo para limpiar las superficies exteriores Puede usar un cepillo de cerdas suaves para re...

Page 26: ...BSP 3200 Generador 26 NOTAS...

Page 27: ...solina 5 Gasolina vieja 6 El alambre de la buj a no est conectado 7 Buj a en mal estado 8 Agua en la gasolina 9 Exceso de cebado 10 Mezcla de combustible excesivamente rica 11 V lvula de toma atascada...

Page 28: ...o que pode resultar em dano para o equipamento Siga as mensagens de seguran a para evitar ou reduzir os riscos de ferimentos ou morte O exaustor do motor deste produto cont m subst ncias qu micas conh...

Page 29: ...letr lito da bateria cont m um cido que extremamente c ustico O contato com o fluido da bateria pode causar graves queimaduras qu micas PERIGO N o toque nas superf cies quentes Deixe o equipamento esf...

Page 30: ...a no motor Interruptor Deixe este interruptor na posi o On antes de usar a partida com o cord o Ajuste o interruptor em Off para desligar o motor Tampa de leo Para adicionar leo no motor Tanque de Com...

Page 31: ...combust vel Use gasolina COMUM no motor do gerador N o use gasolina aditivada N o misture leo na gasolina Limpe a rea em volta da tampa do tanque e remova a tampa Entorne lentamente a gasolina normal...

Page 32: ...necte todas as cargas el tricas do gerador Siga as etapas de instru o de partida na ordem num rica 1 Coloque a v lvula de combust vel na posi o ON Figura 19 2 Coloque a alavanca do afogador na posi o...

Page 33: ...va120 240 V CA 30 A Use um plugue semelhante ao NEMA L 14 20 nesta tomada Conecte um cabo com 4 fios para cargas de 250 V CA a 20 A ou mais ao plugue Figura 23 Voc pode usar o mesmo cabo se usar uma c...

Page 34: ...tenha 3 Permita que a sa da do gerador se estabilize motor funcionando suavemente e equipamentos conectados operando corretamente 4 Conecte e ligue a pr xima carga 5 Novamente permita que o gerador se...

Page 35: ...o ac mulo de sujeira nos enrolamentos internos do gerador podem futuramente reduzir a resist ncia de isolamento dos enrolamentos Limpeza do Gerador Use um pano mido para limpar as superf cies externa...

Page 36: ...BSP 3200 Gerador 36 NOTAS...

Page 37: ...6 Cabo de vela n o conectado 7 Vela com defeito 8 gua na gasolina 9 Afogamento 10 Mistura muito rica 11 V lvula de aspira o travada na posi o aberta ou fechada 12 Motor perdeu compress o 1 Chave na po...

Page 38: ...tras Exclus es Tamb m est o exclu dos desta garantia itens gastos como acopladores r pidos dispositivos de leo cintos an is de veda o filtros embalagem da bomba etc bombas que tenham funcionado sem gu...

Page 39: ...e de la bomba etc las bombas que se hagan funcionar o trabajar sin agua o da os y malfuncionamientos que resulten de accidentes abusos modificaciones alteraciones un servicio inadecuado congelamiento...

Page 40: ...such as quick couplers oil gauges belts o rings filters pump packing etc pumps which have been run without water supplied or damage or malfunctions resulting from accidents abuse modifications alterat...