BSP 3200 Generator
9
SPECIFICATIONS
Maximum Surge Watts . . . . . . . . . . . . . . . 4,550 Watts
Continuous Wattage Capacity . . . . . . . . . . 3,200 Watts
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous Load Current
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . 26.7 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . .13.3 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . 60 Hertz
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . 96 lbs.
MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.
Engine Maintenance
See engine owner’s manual for instructions.
CAUTION!
Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: Do Not use a garden hose to clean the generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
To Clean the Generator
• Use a damp cloth to wipe exterior surfaces clean.
• Soft, bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
STORAGE
The unit should be started at least once every seven days
and allowed to run at least 30 minutes. If this cannot be
done and you must store the unit for more than 30 days,
use the following guidelines to prepare it for storage.
Generator Storage
• Clean the generator as outlined in “To Clean the
Generator” on this page.
• Check that cooling air slots and openings on generator
are open and unobstructed.
CAUTION!
Storage covers can be flammable.
Do Not place a storage cover over a hot
generator. Let the unit cool for a sufficient time
before placing the cover on the unit.
Engine Storage
See engine owner’s manual for instructions.
Other Storage Tips
• To prevent gum from forming in fuel system or on
essential carburetor parts, add fuel stabilizer into fuel
tank and fill with fresh gasoline. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
• Do Not store gasoline from one season to another
unless it has been treated as described above.
• Replace fuel container if it starts to rust. Rust and/or dirt
in fuel can cause problems if it's used with this unit.
• Store in clean and dry area.
Summary of Contents for 1773-0
Page 11: ...BSP 3200 Generator 11 NOTES...
Page 12: ...BSP 3200 Generator 12 SCHEMATIC...
Page 13: ...BSP 3200 Generator 13 WIRING DIAGRAM...
Page 14: ...BSP 3200 Generator 14 EXPLODED VIEW MAIN UNIT...
Page 17: ...BSP 3200 Generator 17 NOTES...
Page 26: ...BSP 3200 Generador 26 NOTAS...
Page 36: ...BSP 3200 Gerador 36 NOTAS...