BSP 3200 Generator
6
GROUNDING THE
GENERATOR
The National Electric Code requires the frame and
external electrically conductive parts of the generator be
properly connected to approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For this purpose, a grounding wing nut (Figure 2) is
provided on the cradle.
Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth–driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. However, local codes may vary widely. Consult with
a local electrician for grounding requirements in your area.
Be sure to keep the ground wire attached while you
connect the electrode.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices, especially when the unit is
equipped with a wheel kit. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.
OPERATING THE
GENERATOR
CAUTION!
Never start or stop unit with
electrical loads connected AND with the connected
devices turned ON.
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instruction steps by numerical order:
1.
Turn the fuel valve to the “On” position (Figure 3).
2.
Place the choke lever in the “Choke” position
(Figure 4).
3.
Set the rocker switch to “On” position (Figure 5).
4.
Grasp the recoil handle and pull slowly until slight
resistance is felt.Then pull rapidly to start engine.
5.
Move choke lever to “Run” position a short distance
at a time over several seconds in warm weather or
minutes in cold weather. Let engine run smoothly
before each change. Operate with choke in “Run”
position.
NOTE: If engine still fails to start after 3 pulls, check for
proper oil level in crankcase.This unit is equipped with a
low oil device that will not allow the engine to start. See
engine manual.
Refer to the engine owner’s manual for complete
starting instructions.
Fuel Valve is shown
in the On position
Figure 3 — Fuel Valve
Figure 5 — Rocker Switch
Figure 4 — Choke Positions
Rocker Switch is
shown in On position
Figure 2 — Grounding Wing Nut
Grounding
Wing Nut
Summary of Contents for 1773-0
Page 11: ...BSP 3200 Generator 11 NOTES...
Page 12: ...BSP 3200 Generator 12 SCHEMATIC...
Page 13: ...BSP 3200 Generator 13 WIRING DIAGRAM...
Page 14: ...BSP 3200 Generator 14 EXPLODED VIEW MAIN UNIT...
Page 17: ...BSP 3200 Generator 17 NOTES...
Page 26: ...BSP 3200 Generador 26 NOTAS...
Page 36: ...BSP 3200 Gerador 36 NOTAS...