To Restore Power Using Extension Cords
1. Only use grounded cords marked for outdoor use
rated for your loads.
To provide power using
extension cords
Total
Amperage
Minimum Guage, Outdoor Rated
Up to 50 FT (15 M)
Up to 100 FT (30 M)
Up to 13A
16
14
Up to 15A
14
12
Up to 20A
12
10
Up to 30A
10
8
2. Follow cord safety instructions.
3. Install carbon monoxide alarm(s).
4. When operating generator with extension cords, make
sure it is located in an open, outdoor area, at least
20 ft. (6.1 m.) from occupied spaces with exhaust
pointed away.
5. Extension cords running directly into home, powering
indoor items IS NOT RECOMMENDED.
DANGER!
Engine exhaust contains carbon
monoxide, a poisonous gas that will kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
• Extension cords running directly into the home
increase your risk of carbon monoxide poisoning
through openings.
• If an extension cord running directly into the home is
used to power indoor items, the operator recognizes
that this increases the risk of CO poisoning to people
inside the home and assumes that risk.
6. Install a listed* transfer switch as soon as possible
if generator will be used to provide home power
restoration.
To Restore Home Power Using a Listed
Transfer Switch
Connections to your home’s electrical system must use a
listed* transfer switch installed by a licensed electrician.
The connection must isolate the generator power from
the utility power and comply with all applicable laws and
electrical codes. Power your home with a 30 Amp transfer
switch system.
Equipment Description
120V
OUTLET
120/240V
Outlet
—
Transfer
Switch
Typical Indoor Items
* Certified by a Nationally Recognized Testing Laboratory
that the product complies to appropriate product safety test
standards.
Summary of Contents for 030750
Page 16: ...N o t f o r R e p r o d u c t i o n EN16 BRIGGSandSTRATTON COM Notes...
Page 19: ...N o t f o r R e p r o d u c t i o n EN19 Troubleshooting Schematic Model 030750 8000 Watts...
Page 38: ...N o t f o r R e p r o d u c t i o n FR18 BRIGGSandSTRATTON COM Remarques...
Page 39: ...N o t f o r R e p r o d u c t i o n FR19 FR19 Remarques...