Register Definition 59
REG_PWM_HZ Definition
31
14 13
0
REG_PWM_HZ Definition
Address: 0x1024C0
Reset Value: 0xFA
Note:
Bit 0 - 13 : These bits define the backlight PWM output frequency in HZ. The
default is 250 Hz after reset. The valid frequency is from 250Hz to 10000Hz.
R/W
Reserved
Register Definition 60
REG_INT_MASK Definition
31
8 7
0
Note: Please read the datasheet section "Interrupts" for more details.
Bit 0 - 7 : These bits are used to mask the corresponding interrupt. 1 means to
enable the corresponding interrupt source, 0 means to disable the
corresponding interrupt source. After reset , all the interrupt source are eligible
to trigger interrupt by default.
Reserved
R/W
REG_INT_MASK Definition
Address: 0x1024A0
Reset Value: 0xFF