FT800 Series Programmer Guide
Version 2.1
Document Reference No.: BRT_000030 Clearance No.: BRT#037
54
Copyright © Bridgetek Limited
Register Definition 31 REG_TOUCH_TRANSFORM_A Definition
31 30
16 15
0
R/W
REG_TOUCH_TRANSFORM_A Definition
Address: 0x10251C
Note: This register represents fixed point number and the default
value is +1.0 after reset.
Bit 0 - 15 : The value of these bits represents the fractional part of the
fixed point number.
Bit 16 - 30 : The value of these bits represents the integer part of the
fixed point number.
Bit 31 : The sign bit for fixed point number
Reset Value: 0x10000