15
800-999-5456
TROUBLESHOOTING
1. Remove bottom of pedal. Check plastic arm to see if it is tight on the bolt that runs through it.
If it is not, push plastic arm to the bottom of pedal and tighten the set screw in the base of
the arm. [ Fig A ]
2. Turn the blue “LO” disc clockwise until wheel head stops rotating. [ Fig B ]
The following is a list of the most common concerns that may be experienced while using your brent®
potter’s wheel. Most of these difficulties occur as a result of normal “wear and tear” and can be solved
with ease. Our brent® wheels have up to a ten year warranty on in-house service and parts.
If you have any questions or need to order replacement parts,
contact the AMACO/brent Technical Support Department at 800-999-5456.
A
B
1. Ensure that the direction switch is not in neutral, if this does not solve the problem continue
to step 2.
SWITCH POSITIONS: Reverse / Neutral / Forward
2. Disconnect from the power supply.
3. Check the fuse and replace if blown. (see page 14)
4. If there is power to the control box and the fuse if fine, please call brent repair for assistance.
Note: Always unplug your wheel when it is not in use to protect
against power surges and lightning storms.
WHEEL HEAD
STILL ROTATES
WHEN PEDAL
IS OFF
WHEEL DOES
NOT ROTATE
WHEN POWER
IS ON