background image

AWT35-100089 Rev AA 

 

28/25 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brecknell USA 

1000 Armstrong Dr. 

Fairmont MN 56031    

Toll free:800-637-0529 

Tel:507-238-8702   

Fax:507-238-8271 

Email:[email protected] 

http://brecknellscales.com

 

Brecknell UK 

Foundry lane, 

Smethwick, West Midlands 

England, B66 2LP 

Tel:+ 44 (0) 8452 466717   

Fax:+44 (0) 8452 466718  

Email:[email protected]  

http://brecknellscales.com  

 

 

 

Summary of Contents for 810036380263

Page 1: ...Model MS 1000 LCD Operator Manual AWT35 100089 Rev AA...

Page 2: ...roduct names used within this document are trademarks or registered trademarks of their respective holders Groupe de soci t s Avery Weigh Tronix 2021 Tous droits r serv s Aucune partie de cette public...

Page 3: ...mple Weighing 9 3 2 Tare Weighing 9 3 3 Changing Units 9 3 4 BMI Function 10 3 5 Print Function Com Ports 10 3 6 Hold Function 10 3 6 1 Automatic Hold Mode Default 11 3 6 2 Average Hold Mode 11 3 6 3...

Page 4: ...AWT35 100089 Rev AA 4 25 Manual revision history Current Issue Date Created Details of Changes AWT35 100089 Rev AA Sep 2021 New...

Page 5: ...he mains lead must be connected to a supply outlet with a protective earth contact The electrical supply at the socket outlet must provide over current protection of an appropriate rating For your pro...

Page 6: ...place the MS1000 platform in a location that will not degrade its accuracy Try to avoid placing the scale in direct sunlight or near air vents Place the scale on a level flat surface It is not advise...

Page 7: ...of measure Battery status or AC DC operated 2 5 2 Operation Keys The key functions are listed below In menu mode the keys have secondary functions Enters exits the HOLD mode In Menu mode go to previou...

Page 8: ...AWT35 100089 Rev AA 8 25 Zeroes the scale turns the scale on off In Menu mode cancel an operation and exit from the current working mode...

Page 9: ...wer up the scale and zero the display if necessary by pressing the ZERO ON OFF key Be sure the scale is displaying weight in your preferred unit of measure Press the UNIT key if necessary 2 Place the...

Page 10: ...full duplex RS 232 serial port and USB port designed for connection to either a PC or a serial printer The Print function sends the data out to the RS232 USB ports Use the correspondent adapter to con...

Page 11: ...weighments 5 Press the HOLD key to exit the current mode If the weight oscillations exceed the HLD RNG division range value 5 div within the STB TIM time value 15 sec the indicator will display STB ER...

Page 12: ...LD key to enable this function The Hold annunciator flashes 3 Step on the scale If the weight sensed is stable for STB TIM 15 s and above the NLD RNG zero range 10 div 5 lb 2 kg the indicator displays...

Page 13: ...TARE key to confirm or the ZERO ON OFF key to cancel the operation exit the menu 4 1 1 User Options USER SubMenu1 SubMenu2 Option Default Description RESET NO NO NO Returns the USER parameter to the f...

Page 14: ...GLE EH SCP SCP 12 Eh sp2 Lfuulf Lfuu Lf lf Lf uulf uu lf USB Port com2 BAUD RT 600 9600 Sets the baud rate of com2 1200 2400 4800 9600 19200 BYT FMT 8N1 8N1 Sets the bits format of com2 7O1 7E1 7O2 7E...

Page 15: ...OMPAR mode NONE NONE COMPARE function modes NONE disabled See SBI 210 LCD Operation Manual and Config Compar L LOW IN LMT O HIGH OUT LMT HOLD Function HLD MOD NONE AUTO Enables the HOLD function mode...

Page 16: ...div range can be averaged NLD RNG No Load Detected Range 1 255 10 Sets the weight range that the indicator considers as the Zero range for the relevant function e g Auto Hold Mode 1 255 the range of...

Page 17: ...cator displays 2 TD 55 and the serial port continuously transmits 0x55 Use the and keys to change the character USB RD USB receive data testing same as RS232 receiving data testing USB TD USB send dat...

Page 18: ...the TARE key to confirm or the ZERO ON OFF key to cancel the operation exit the menu CAL SubMenu1 SubMenu2 Option Description ZERO Adjusts the CAL P0 point only LINE CAL P0 Stores the Zero calibration...

Page 19: ...platform 9 Press the TARE key to store the CAL P1 Point 10 Press the TARE key to save the calibration points and exit the Calibration mode or press the PRINT key to add CAL P2 3 points On calibration...

Page 20: ...dary unit of measure 1 div 0 2 kg is automatically determined by the indicator according to the first unit PRIM Ut kg lb lb Selects the primary unit of measure kg or lb The default calibration unit is...

Page 21: ...ght is outside the IZSM range DSP OVR if the initial zero is over range display the 0 error WEIGHT current weight CAL ZRO calibration zero LAST Z T last zero tare value WEIGHT CAL ZRO LAST Z T SAZSM 0...

Page 22: ...25 COMPAR YES NO NO No disabled See SBI 210 LCD Operation Manual ACCUMU NO MANUAL AUTO NO No disabled See SBI 210 LCD Operation Manual GEO CAL YES YES Yes enables the Geographical Adjustment Factor i...

Page 23: ...9V 600MA adaptor body with USA plugs included and 6xAA batteries not included Operating temperature range 32 104 F 0 40 C max relative humidity 80 at 86 F 30 C Communication interface RS 232 USB Port...

Page 24: ...r 1 initial zero error 1 low battery 4 always 1 always 1 always 1 always 1 5 always 1 always 1 always 1 always 1 6 always 0 always 1 always 1 always 0 7 parity Parity parity Parity Command Response AS...

Page 25: ...weighing range 1 Over capacity 2 0 Within weighing range 1 Under zero 3 0 Within range 1 Outside zero capture range 4 0 Not at center of zero 1 Center of zero 5 always 1 6 always 1 7 parity Command Re...

Page 26: ...ty 1 Not at zero 0 Not over capacity 2 0 RAM error 1 ROM error 1 RAM okay 0 ROM okay 3 0 EEPROM error 1 Faulty calibration 1 EEPROM okay 0 Calibration okay 4 Always 1 Always 1 5 always 1 always 1 6 al...

Page 27: ...D Simulate ZERO key no response from scale others Un known commands LF CR EH SP2 MM Status Byte gg Scale in motion GG Stable weight data Command Response ASCII HEX CR 0d Read scale weight P W1W2W3 dp...

Page 28: ...ll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 Email sales brecknellscales com http brecknellscales com Brecknell UK Foundry lane Smethwick West Midlands England B66 2LP Tel 44 0 8452 466717 F...