The indicator provides special mode settings to accommodate weight
movements in the User Menu. Open the Submenu 1
and change the parameter values: NLD.RNG (10
div), HLD.RNG (5
div), AVG.TIM
(5
sec), STB.TIM (15
sec) accordingly.
3.6.1 Automatic Hold Mode (Default)
1. Power up the scale and zero the display, if necessary, by pressing the
ZERO/ON/OFF
key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the
UNIT
key, if
necessary.
2. Press the
HOLD
key to enable this function
The
Hold
annunciator flashes.
3. Step on the scale
If the weight sensed is above the
NLD.RNG
zero range (10 div = 5 lb, 2 kg) and doesn’t exceed
the
HLD.RNG
oscillations range (5 div = 2.5 lb, 1 kg) within the
AVG.TIM
average time (5 sec),
the indicator calculates and displays the
Hold
mode weight.
The
Hold
annunciator stops flashing.
4. Remove the item(s) from the scale platform and repeat the steps above for other
Hold
weighments.
5. Press the
HOLD
key to exit the current mode.
If the weight oscillations exceed the HLD.RNG division range value (5 div)
within the STB.TIM time value (15 sec), the indicator will display STB.ER. See
3.6.2 Average Hold Mode
1. Power up the scale and zero the display, if necessary, by pressing the
ZERO/ON/OFF
key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the
UNIT
key, if
necessary.
2. Press the
HOLD
key to enable this function
The
Hold
annunciator flashes.
3. Step on the scale
If the weight sensed is above the
NLD.RNG
zero range (10 div = 5 lb, 2 kg) and doesn’t exceed
the
HLD.RNG
oscillations range (5 div = 2.5 lb, 1 kg) within the
AVG.TIM
average time (5 sec),
the indicator calculates and displays the
Hold
mode weight.
The
Hold
annunciator stops flashing.
4. Press the
TARE
key to repeat the
Hold
weighment or the
HOLD
key to exit the current mode.
The scale will automatically exit the
Hold
mode after the
HLD.TIM
time value (default, disabled).
If the weight oscillations exceed the HLD.RNG division range value (5 div)
within the STB.TIM time value (15 sec), the indicator will display STB.ER. See