05
-
2015 Rev.1
10.
68
Parte 10 Ricerca Guasti
W
218
SENS MOT TEMP
KO
Motor temperature sensor out of order
A
248
NO CAN MSG.
The motor does not receive the CAN message from the display
or from
TILLER
A
222
SMARTDRIVER KO
The board does not provide positive EB
W
224
WAITING FOR NODE
Canbus node in alarm
A
69
CURRENT SENS.KO
Current measured in standby higher than expected
W
13
EEPROM KO
Eeprom error
A
30
VMN LOW
Motor output voltage lower than expected
A
74
DRIVER SHORTED
LC coil driver in short circuit or disconnected
A
213
AUX BATT. SHORT.
When the AUX + is controlled by the tiller, the positive is high
and the tiller is updated again
A
234
DRV. SHOR. EV
EV in short circuit
A
37
CONTACTOR DRIVER
Main contact closed
A
75
CONTACTOR DRIVER
LC contact blocked
A
232
CONT. DRV. EV
Valve contactor driver
A
220
KEY OFF SHORTED
Low key
-
off
A
223
COIL SHOR. MC
-
EB
Short circuit in LC or EB
W
235
COIL SHOR. EV.
EV in short circuit
A
38
CONTACTOR OPEN
LC not closed
A
208
TILLER ERROR
Different inputs between hard & soft switch and tiller
W
78
VACC NOT OK
Accelerator value too high, direction/enable switch open.
W
79
INCORRECT START
Wrong starting sequence
W
242
PUMP INC START
Wrong pump drive
W
80
FORW + BACK
Two directions active simultaneously
A
230
EMERGENCY
PAUX connector not connected to the battery or different volt-
age
A
229
POS. EB. SHORTED
High board output when tiller is open
A
233
POWER MOS SHORT
Mosfet power in short circuit
W
245
PUMP VACC NOT OK
High Vacc for the pump
A
236
CURRENT GAIN
The overcurrent gains have not been calibrated
W
200
KEY ON INC.ST. P
Update the pump request when the key is turned
W
201
KEY ON INC.ST. T
Update the drive request when the key is turned
A
237
ANALOG INPUT
Problem in the A/D conversion of C
W
219
DEAD MAN ABSENT
With "Positive EB" parameters at level 2 in the "HW setting"
menu and "Deadman" input
A
195
TILTED
Inclinometer
A
196
OVERLOAD
Overload
A
84
STEER SENSOR KO
Driving controls malfunction
04
-
2020 Rev.01
P
ART 10
TROUBLESHOOTING AND ERROR CODES