Page 18
Operation Notes and Details
The inboard locator automatically
folds down to the platform sur-
face (horizontal) during the stow
function (as platform retracts).
Discontinue lift operation imme-
diately if the inboard locator does
not operate properly.
Outer Barrier:
The outer barrier
provides a ramp for wheelchair
loading and unloading at ground
level (see photos on following
page). When the platform lowers
fully to ground level, the electric
actuator unfolds (rotates) the
barrier to the ramp position (fully
unfolded).
The outer barrier is spring loaded
but driven by the electric actuator
to rotate from the ramp (hori-
zontal) position to the deployed
(vertical) position.
WA
RNING
Discontinue lift use
immediately if any
lift component does
not operate prop-
erly. Failure to do so
may result in serious
bodily injury and/or
property damage.
Although the outer barrier is
lift-powered, activation of the
barrier is controlled by the lift
operator. Pressing the DOWN
switch unfolds the barrier. The
actuator-powered outer barrier
folds (rotates) to the vertical
position when the UP switch is
pressed.
Interlock Feature:
The outer
barrier actuator is designed with
limited capability to prevent fold-
ing when occupied. The lift will
not function if the outer barrier is
occupied.