Disconnect the power cable at the battery prior to servicing. 

Keep hands, arms and all other body parts clear of moving parts.

Never modify (alter) a Braun Corporation ramp.

Replacement parts must be Braun authorized replacements.

Never install screws or fasteners (other than factory equipped).

Whenever replacing a hydraulic cylinder or seals, deploy ramp fully.

Failure to follow these safety precautions may result in serious bodily injury and/or prop-
erty damage.

  Installation/Service Safety Precautions

 (Continued) 

WARNING

Read this manual, 
before performing 
installation, operation 
or service procedures.  
Failure to do so may 
result  in serious 
bodily injury and/or 
property damage.

  Installation Requirements

  

Braun RA300 Ramps must be 
installed and serviced by a Braun 
authorized service representa-
tive who has attended and been 
certi

À

ed by The Braun Corpora-

tion Sales and Service School for 
Braun Mobility Products.

pocket” con

À

guration (not sup-

plied).

Slope:

  The portion of the 

Á

oor 

where the ramp mounts can 
range in slope from 0° to 8° 
(see Figure C).  

Outboard Support Tube:

  An 

outboard support tube must be 
positioned under the outboard 
edge of the opening (minimum 
1-1/2" x  2" steel tube).  See 
Figures C and D.  The recom-
mended height of the support 
tube is 13-3/4" above ground 
level.  

Kneeling Vehicles:

  This 

dimension measured with sus-
pension lowered.  

ADA:

  Installations with the 

support tube positioned higher 
than 13-3/4" above ground 
level may not comply with ADA 
ramp slope requirements. 

Some OEM chassis meet these 
speci

À

cations.  The RA300 

ramp was designed to conform 
to these speci

À

cations.

The ramp pan horizontal border 
(lip) sets on the 

Á

oor pocket pe-

rimeter, (framework, sub 

Á

oor, 

etc.).  The 

À

nished 

Á

ooring can 

be cut to conform to the border 
of the pan for a 

Á

ush transition 

surface from ramp-to-

Á

oor.

RAMP INSTALLATION 

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

  Chassis Requirements

The Braun RA300 Ramp is 
designed for use in low-

Á

oor 

transit vehicles.  A “

Á

oor pocket” 

(mounting hole) built into the 
chassis/

Á

oor system allows 

for simple installation (accepts 
“drop-in” unit). The 

Floor Pocket 

Clear Opening Dimensions

 are 

speci

À

ed on pages 15 and 16.  

See Figures B, C, D and E.  

The ramp installer must provide 
an appropriate framework in the 
applicable location in the vehicle 
(aligned center with passenger 
door opening).  Ramp assembly 
mounting hardware and/or brack-
ets are directly dependant upon 
the vehicle chassis and “

Á

oor 

Read and become familiar with 
the operating instructions and the 
installation instructions contained 
in this manual before beginning 
installation, operation or service 
procedures.

WARNING

Summary of Contents for BF3255Y-12V

Page 1: ...ailure to do so may result in serious bodily injury and or property damage Braun RA300 Transit Ramp Model BF3255Y 12V Commercial Braun RA300 Transit Ramp Model BF3255Y 12V Providing Access to the Worl...

Page 2: ...l includes operating instructions installation instructions servicing instructions and instructions for troubleshooting if needed Braun ramps are built for dependability and will provide years of serv...

Page 3: ...Ramp Operation Safety Precautions 13 14 Installation Instructions Installation Requirements 14 Chassis Requirements 14 Door Opening 15 Obstructions 15 Installation Illustrations 15 17 Electrical Conne...

Page 4: ...terminology Details regarding lift model variations terminology direction and compo nents are provided on pages 4 and 5 As viewed from outside the vehicle LEFT RIGHT OUT IN Ramp Terminology Illustrat...

Page 5: ...Terminology Illustration Cylinder As viewed from outside the vehicle OUT IN RIGHT LEFT Pan Weldment Relays Counter Cable Tension Gas Spring Pump Ramp Drive Arm Cam Microswitch Assembly Cylinder Cable...

Page 6: ...draulic cylinder No sensitive electronic controls or sensors are required for opera tion All RA300 ramp models feature gravity down drift during the deploy cycle When deploying the ramp the motor stop...

Page 7: ...driven three stage drive arm assembly deploys and stows the ramp assembly Ramp Actions and Functions Deploy Deploy is the action of the ramp assembly extending and unfolding to ground level when the D...

Page 8: ...nd bystanders clear of area in which the ramp operates Load and unload clear of vehicular traf c Open ramp door s fully and secure before operating ramp Do not overload or abuse The rated capacity is...

Page 9: ...chair wheels pull wheelie when on the ramp The wheelchair must be positioned in the center of the ramp when loading and unloading Keep ramp owner s manual in ramp mounted vehicle at all times Maintena...

Page 10: ...nformation is included It is the responsibil ity of the attendant to properly open and close the ramp access door s to activate interlock s to properly activate the ramp power functions as well as ass...

Page 11: ...part of your transit agency s daily service program Simple inspections can detect potential operational problems Operation Procedure Review Transit agency supervisors should train and educate all driv...

Page 12: ...atus that does not t on the ramp Do not exceed the 660 pound 300 kilograms load capacity of the ramp Passengers should enter and exit one at a time The attendant should not board the ramp with the pas...

Page 13: ...r and exit the vehicle on the ramp in the safest manner ADA requirements state that transit drivers at tendants must assist with attaching and removing wheelchair and occupant restraint belts Ramp pas...

Page 14: ...fect on the center of gravity The wheelchair passenger s center of gravity and their ability to maintain stability and balance must be kept in mind by the wheelchair passenger and the attendant The ai...

Page 15: ...Symbols SAFETY FIRST Know That C CAUTION This symbol indicates important information regarding how to avoid a hazardous situation that could result in minor person al injury or property damage A suppl...

Page 16: ...and D The recom mended height of the support tube is 13 3 4 above ground level Kneeling Vehicles This dimension measured with sus pension lowered ADA Installations with the support tube positioned hi...

Page 17: ...d to t around the ramp pan horizontal border lip There must be a minimum 1 8 clearance between the deployed ramp assembly and the vehicle oor or any obstruction on the oor such as a rubber sill or thr...

Page 18: ...Floor Pocket Clear Opening Dimensions As viewed from outside the vehicle Left Right Out In Chassis Chassis CL C L MINIMUM DOOR OPENING WIDTH 34 Figure F Vehicle chassis oor pocket con guration must b...

Page 19: ...oyed ramp assembly and the vehicle oor or any obstruction on the oor such as a rubber sill or threshold Chassis Chassis Figure H As viewed from outside the vehicle Left Right Out In Stowed RA300 Ramp...

Page 20: ...IN signal must be terminated in the supplied Deutsch connector The ramp installer provides an appropriate control switch for the end user A momentary contact ramp control switch center off will typica...

Page 21: ...IGNAL TO DEPLOY RAMP MOMENTARY SWITCH D A G E F C B H TO USER DEPLOY 14 GA TO USER STOW 14 GA VEHICLE GROUND 12 GA POWER SOURCE 12 GA D C B A RECOMMENDED WIRE GAUGE COLOR WIRING PROVIDED BY INSTALLER...

Page 22: ...lent Penetrating Oil Aerosol Can Stainless Stick Door Ease 1 68 oz Style tube Stick tube Inboard Ramp Hinge LO Outboard Ramp Hinge concealed LO Gear and Gear Rack internal DE Note See the Maintenance...

Page 23: ...formed as speci ed by an authorized service technician Failure to do so may result in serious bodily injury and or property damage WARNING cedures and will vary according to ramp use and conditions Tr...

Page 24: ...rm slots for excessive wear or damage Clean ramp and ramp mounting area ensure no debris in area to obstruct stowing stacking Cycle ramp and observe drift speed during deploy and stow functions Inspec...

Page 25: ...r hoses ttings seals etc for leaks if uid level is low Inspect vehicle to ramp wiring harness Mounting Decals and Antiskid Use Braun 32840 QT Exxon Univis HVI 26 hydraulic uid do not mix with Dextron...

Page 26: ...nd the current to the Deploy Relay is interrupted thus stopping the current to the pump motor The platform then drifts downward to ground level during which at some position the Drift Out microswitch...

Page 27: ...rther before pump shuts off Drift Out Microswitch Cam 2 Turn Cam 2 clockwise to start Drift Out function sooner shut pump off Turn Cam 2 counter clockwise to start Drift Out function later allow ramp...

Page 28: ...valve is preset at 1000 psi The Stow pressure relief valve is preset at 1250 psi Do not tamper with this adjustment unless absolutely necessary will not stow or deploy ramp and then only after contac...

Page 29: ...OUT Cam Adjustment Procedures Drift OUT Speed Cam 1 Drift out cam controls the speed that the ramp moves when the ramp is almost fully deployed and the motor shuts off 1 Loosen the set screw in the dr...

Page 30: ...e Check for loose terminals or broken wire Correct or replace Disconnect harness from ramp Using volt meter test probe 8 pin Deutsch male plug terminals as follows Pin A 12 24 V Pin B Ground Pin C V w...

Page 31: ...hysical obstruction 20 lb or more on ramp 2 32 Mechanical binding 2 33 Deploy pressure relief valve setting too low 2 34 Low hydraulic uid supply Note Fluid should be changed if there is visible conta...

Page 32: ...contamination or other wise damaged 4 51 See 2 40 4 61 See 2 40 and 2 50 4 71 See 2 35 2 36 and 2 62 Adjust or replace See Microswitches in Systems Descriptions for details Connect repair or replace A...

Page 33: ...Page 31 BLANK for LAYOUT...

Page 34: ...A300 TRANSIT RAMP ASSEMBLY POWER CONNECTIONS CONTROL SIGNALS PROVIDED BY INSTALLER SYMBOL KEY DRIFT OUT MICROSWITCH DEPLOY RELAY COUNTER 14 GA BL BK 12 GA 12 GA 12 GA RECOMMENDED WIRE GUAGE GROUND 12...

Page 35: ...SOURCE 12 GA TO DEPLOY INDICATOR 14 GA TO STOW INDICATOR 14 GA PLUG NOT USED PLUG NOT USED 4 3 2 1 COLOR LOC COUNTER WIRE CODE COUNTER 87 87a 30 85 86 COM N O N C COLOR PIN MICROSWITCH CONN N C N O CO...

Page 36: ...0 Pump Motor Bidirectional Flow Control Valve Fixed Orifice 3 Way 2 Position Shuttle Valve M M Description Symbol Reservoir Vented Relief Valve Check Valve Hydraulic Port Filter Screen 86 BAR 1250 PSI...

Page 37: ...006 5 2 Hose Assembly 10 1 8 Dia SW SW 16004A 010 6 3 Hose Assembly 12 1 8 Dia SW SW 16004A 012 7 2 Hose Assembly 28 1 8 Dia SW SW 16004A 028 8 9 Elbow 45 7 16 20 7 16 20 SAE Male O Ring 24505 9 2 Tee...

Page 38: ...__V Hydraulic RA300 33364 42 3 Bolt 3 8 16 x 1 2 316SS Hex BF00249 43 1 Plate Tapped 4 40 Microswitch 24998 44 85 Screw 10 32 x 3 8 FL HD HX SKT Auto Black 24537 45 3 Microswitch Sealed 30205 46 1 Sp...

Page 39: ...6 18 6 14 56 57 67 61 76 61 61 61 14 15 50 15 11 74 74 4 24 44 44 24 24 5 6 17 7 6 7 10 16 60 61 69 67 73 64 61 72 65 66 66 62 66 69 67 71 61 8 8 9 41 44 75 42 19 20 21 22 22 23 24 24 61 61 24 24 24...

Page 40: ...ed View Deployed View Power Unit Hydraulic Pump Module Voltage 12 VDC Current 30 Amps Max Inputs Required 12 Volt Supply Ground Ramp Out Signal Ramp In Signal Interlock Signal Notes Mounting holes bra...

Page 41: ...ormal speed Is the lift power source adequate Do the drive arms clear the ramp and housing Is ramp operation quiet no rattles abnormal sounds etc Are the ramp posted decals worn missing or illegible I...

Page 42: ...Over 300 Braun Dealers Worldwide Providing Access to the World Providing Access to the World International Corporate Hdqrs P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670...

Page 43: ...ed Braun dealer completes the warranty work The warranty registration card accompanying this ramp is to be completed and returned to The Braun Corporation within 20 days of purchase If Braun receives...

Reviews: