![Braun Corporation BF3255Y-12V Operator, Installation, Service Manual Download Page 32](http://html1.mh-extra.com/html/braun-corporation/bf3255y-12v/bf3255y-12v_operator-installation-service-manual_2805212032.webp)
Page 30
3.00
STOW
(In)
FUNCTION
SYMPTOM
POSSIBLE
CAUSE
REMEDY
TROUBLESHOOTING
3.11 See 1.00
3.12 Drift In Microswitch out of adjust-
ment or damaged
3.13 Drift In Microswitch harness discon-
nected, damaged or otherwise
damaged
3.21 Ramp was stopped within the
Stow “Drift In” range during Deploy
function
3.41 See 2.31, 2.32, 2.34, 2.35 and 2.36
3.42 Stow pressure relief valve setting
too low
3.43 Stow pressure relief valve stuck
open due to contamination or other-
wise damaged
4.51 See 2.40
4.61 See 2.40 and 2.50
4.71 See 2.35, 2.36 and 2.62
Adjust or replace. See Microswitches in
Systems Descriptions for details
Connect, repair or replace
Activate Deploy function until ramp is
out of the Stow “Drift In” range. Then
activate Stow function.
Adjust relief valve setting. See Systems
Descriptions for details.
Contact Braun Product Support - re-
place pump
3.60
Drifts
Excessively
Slow
(or No Drift)
3.70
Drifts
Excessively
Fast
3.50
Faulty or
Sluggish
Operation
3.40
Pump Runs
But
Doesn’t
Stow
3.10
No
Operation
3.20
Locked in
Intermediate
Position
(No Response to
Stow Switch/No
Drift In)
Summary of Contents for BF3255Y-12V