18

3

ADDITIONAL 

OPERATION FEATURES

cont.

3.6

  

Extended Hold (Vacation) Mode

1.

 Press the 

HOLD

 button to bypass the program schedule. The current set point temperature will be held until    

  the HOLD condition

 

is released. 

HOLD

 will show in the display.

2.

 Press the 

HOLD

 button again to return the thermostat to normal program operation.

3.

 The hold period lasts until the hold is released as in step number 2 above, or is limited to 24 hours if the 

  default was changed during programming of user settings (section 2.4.5).

NOTE:

  

Extended Hold Mode is not available if the thermostat is in the non-programmable mode.

3.7

  

Filter Check Monitor 

(see section 2.4.2 for setting)

The Filter Check Monitor displays a reminder for required filter 
replacement or cleaning, by flashing the 

FILTER

 segment in the 

display. See instructions on your filter or heating/cooling unit for 
recommendations for interval setting. When the selected interval 
has been reached, and required cleaning or replacement has been 
performed, press the 

RETURN

 button in any normal mode to reset 

the timer and turn off the warning.

3.8

 

UV Light Monitor 

(see section 2.4.3 for setting)

The UV Light Monitor displays a reminder for required replacement 
of the bulb by flashing the UV segment in the display. See instructions 
provided with your UV source for recommendations on interval 
setting. When the selected interval has been reached and required 
replacement has been performed, press the 

RETURN

 button in any 

normal mode to reset the timer and turn off the warning.

19

3

ADDITIONAL 

OPERATION FEATURES

cont.

3.9

  

Humidifier Pad Monitor 

(see section 2.4.4 for setting)

The Humidifier Pad Monitor displays a reminder for required 
replacement of the humidifier pad by flashing the 

HUMID PADS

 

segment in the display. See instructions on your filter or heating/
cooling unit for recommendations for interval setting. When the 
selected interval has been reached, and required service has 
been performed, press the 

RETURN

 button in any normal mode to 

reset the timer and turn off the warning.

3.10

  

To Lock or Unlock the Keypad

Press and hold both the    and    buttons at the same time. Lock 
will flash. Continue to hold the    and    buttons for 5 seconds.  
The display will change to 000 as shown in Figure A. The factory 
code is 555. Using the    button, change the first digit to 5 and 
press the 

RETURN

 button. Using the same buttons (    and 

RETURN

), 

change the second and third digit to 5. Pressing 

RETURN

 on the 3rd 

digit does the following: the keypad will change to lock if it was 
locked, or unlock if it was locked (Figure B). If the incorrect code is
entered, the display will show “

no

” (Figure C). See section 2.4.8 for 

instructions on how to add a new unlock code.  

Figure A

Figure B

Figure C

Summary of Contents for Premier 5400

Page 1: ...e timer and recirculating fan to default settings Button Turns on backlight for 10 seconds Button Increases setting time temperature etc Scrolls between option settings Button Decreases setting time temperature etc Scrolls between option settings 1 1 2 3 4 5 6 7 9 10 model 5400 shown with cover open 8 9 7 1 6 2 3 4 5 10 MODEL 5400 2008 Braeburn Systems LLC Patents Pending All Rights Reserved Pub N...

Page 2: ...SET 2 2 PROGRAMMING USER SETTINGS 2 3 Setting Thermostat System Selection The system can be selected by pressing the System button There are five possible settings to select from AUTO COOL OFF HEAT and EMER AUTO Auto can only be selected if it was enabled by the installer see Section 4 of the Installer Guide If AUTO is selected the system cycles between heating and cooling as determined by the set...

Page 3: ...n again and the LCD display will show d3 SET X where X equals the F C differential setting This is the current third stage differential setting 6 Press the or button to set the third stage differential to your desired setting of 1 2 3 4 5 or 6 F 0 5 1 0 1 5 2 0 2 5 or 3 0 C 4 2 PROGRAMMING USER SETTINGS cont 5 2 4 2 Setting the Filter Check Monitor see also section 3 7 The default setting is 0 day...

Page 4: ...e X is the temporary override limits 18 Press the or button to change the Temporary Override Time Limit to the desired value of 4 3 2 or 1 hour 2 4 8 Setting the Multi Level Keypad Lockout Code see section 3 10 19 Press and hold the RETURN button for four seconds Press RETURN button repeatedly until 000 SET LOCK is displayed 20 Press the or button to enter a 3 digit code using the RETURN button to...

Page 5: ...mming mode was selected during the Installer Setup Installer Guide the default program is the 2 events per day shown in the chart above Weekday Weekend MORN DAY EVE NIGHT Time 6 00 pm Heat 70 F 21 C Cool 75 F 24 C Time 8 00 am Heat 62 F 17 C Cool 83 F 28 C Time 6 00 am Heat 70 F 21 C Cool 75 F 24 C Time 10 00 pm Heat 62 F 17 C Cool 78 F 26 C 4 Event Time 6 00 pm Heat 70 F 21 C Cool 75 F 24 C Time ...

Page 6: ...le in auto changeover mode When you place the system in the HEAT or COOL modes of operation an appropriate indicator will appear in the LCD display when the system is running When you place the system in the OFF mode the display will indicate OFF NOTE If the PROG button is pressed while AUTO is selected the thermostat will switch from the AUTO mode to the mode currently in the display NOTE If Auto...

Page 7: ...utomatically 2 PROGRAMMING USER SETTINGS Entering Your Program 7 DAY Commercial Mode 1 Press the PROG button to enter the Program setting mode Press the SYSTEM button to select HEAT to set heating times and temperatures OCC occupied set point of the Whole Week will be displayed The display will show M TU W TH F SA SU to indicate the whole week is being programmed The hour portion of the set point ...

Page 8: ...r portion of the set point time and the AM PM indicator will be flashing 6 Follow steps 3 through 5 to set the set point times temperatures and fan mode for the periods of DAY EVE and NIGHT 2 PROGRAMMING USER SETTINGS cont 15 Entering Your Program 5 2 DAY Residential Mode continued 7 After pressing the PROG button you will enter the Weekend Program Group The display will show SA SU to indicate the...

Page 9: ...talled at setup the display temperature is either the temperature at the sensor or an average of the temperature at the sensor and the temperature at the thermostat 17 cont 3 ADDITIONAL OPERATION FEATURES 3 4 Remote Outdoor Sensor if installed The Braeburn Remote Outdoor Sensor is used for determining if balance points have been exceeded humidity control and for outdoor temperature display It is n...

Page 10: ...y See instructions provided with your UV source for recommendations on interval setting When the selected interval has been reached and required replacement has been performed press the RETURN button in any normal mode to reset the timer and turn off the warning 19 3 ADDITIONAL OPERATION FEATURES cont 3 9 Humidifier Pad Monitor see section 2 4 4 for setting The Humidifier Pad Monitor displays a re...

Page 11: ... used The proper operation of this function is preprogrammed into this thermostat No user changes are necessary 20 3 ADDITIONAL OPERATION FEATURES cont 3 11 Adaptive Recovery Mode ARM In order to maximize comfort and energy efficiency this thermostat is equipped with Adaptive Recovery Mode ARM This feature minimizes the amount of time required by the heating or cooling system to reach the new set ...

Page 12: ... Limits limit how much the thermostat can be adjusted from the program set points when the thermostat is used in the programmable mode This will not allow the user to set a temporary override in the heat or cool mode past the limit from the program set points The Temporary Override Adjustment Limits can only be used in the non programmable mode when the security level is at level 1 This will not a...

Page 13: ...m Fan continues to run in cooling mode when the system has turned off Potential Solution The Residual Cooling Fan Control Feature can allow up to a 90 second fan delay after cooling system shutdown for energy efficiency gains The default setting is 60 seconds This can be changed to disable this feature or shorten the time period if desired see section 4 of the Installer Guide Symptom Thermostat do...

Page 14: ...digit press the RETURN key for 1 second The display will return to the normal mode If an incorrect code is entered the display will flash no Symptom Keypad does not function Potential Solution Keypad is locked check for LOCK segment in display Symptom Thermostat will not follow program set points Potential Solutions Check current time of day day of week program settings Verify AM PM indicator is a...

Page 15: ... set point is limited Potential Solution Override limit was set in user options see section 2 4 7 Symptom Heating or cooling set point cannot be raised above a certain limit Potential Solution Set point limit was set in installer options Symptom Heating or cooling system turns on ahead of scheduled program times Potential Solution Adaptive recovery mode was enabled in installer options 5YEAR WARRA...

Reviews: