TROUBLESHOOTING

cont.

Symptom:

  

LO

 is shown in the thermostat display where the room temperature is normally displayed.

Potential Solutions:  

The temperature sensed by the thermostat is lower than the 40˚ F (5˚ C) lower limit of the 

thermostat’s display range. The display will return to normal after the sensed temperature rises within the 40˚ to 99˚ F 
(5˚ to 37˚ C) display range. If the temperature in the controlled space seems to be normal, wait for the thermostat to 
acclimate to the correct room temperature. If the room seems to be colder than usual, turn on the heating system to 
raise the temperature as needed for comfort within the room.

This condition could occur from the system being turned off during a cold weather period or upon installation when 
the thermostat has been stored for a long period of time in a cold vehicle or location prior to being installed. The 
thermostat should be allowed to warm up prior to installation in order to provide proper heating control once installed.

Symptom:  

Fan continues to run all the time whether the system is on or off.

Potential Solution:

  

Verify that the fan is programmed to run in 

AUTO

 mode. This will allow the fan to run only 

when the heating or cooling system is turned on and running.

Check thermostat wiring to make sure that the fan control wiring is connected to the correct terminals on the 
wiring terminal block (see section 6 of the Installer Guide).

Symptom:

  Unit will not enter program mode.

Potential Solution:  

Non-Programmable mode was selected during Installer Setup (see section 4 of the Installer Guide).

 

Symptom:  

Air conditioning stays on after set point is reached. 

Potential Solution: 

 

Dehumidification control is enabled (see section 3.17).

Symptom:  

Temporary override of the program set point is limited.

Potential Solution:  

Override limit was set in user options (see section 2.4.7).

Symptom: 

 Heating or cooling set point cannot be raised above a certain limit.

Potential Solution:  

Set point limit was set in installer options.

Symptom:

  

Heating or cooling system turns on ahead of scheduled program times.

Potential Solution:  

Adaptive recovery mode was enabled in installer options.

 

         

5

YEAR

 

WARRANTY

LIMITED

Store this 

booklet for

future reference

©2008 Braeburn Systems LLC • Patents Pending • All Rights Reserved.    Pub. No. 5400-110-001

Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are 

due  to  faulty  material  or  workmanship  for  a  period  of  five  years  after  the  original  date  of 

purchase by a professional service technician. This warranty and our liability does not apply to 

batteries,  nor  does  it  include  damage  to  merchandise  or  the  thermostat  resulting  from 

accident,  alteration,  neglect,  misuse,  improper  installation  or  any  other  failure  to  follow 

Braeburn installation and operating instructions.

Braeburn  Systems  LLC  agrees  to  repair  or  replace  at  its  option  any  Braeburn  thermostat 

under warranty provided it is returned postage prepaid to our warranty facility in a padded 

carton  within  the  warranty  period,  with  proof  of  the  original  date  of  purchase  and  a  brief 

description of the malfunction. This limited warranty does not include the cost of removal or 

re-installation.

This warranty gives you specific legal rights and you may also have other rights that vary from

state to state or province to province. Answers to any questions regarding our limited warranty 

may be obtained by writing our corporate offices.

Braeburn Systems LLC 
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)

WARRANTY FACILITY:

  Braeburn Systems LLC

 

Attn: Warranty Department

 

2215 Cornell Avenue

 

Montgomery, IL 60538

Summary of Contents for Premier 5400

Page 1: ...e timer and recirculating fan to default settings Button Turns on backlight for 10 seconds Button Increases setting time temperature etc Scrolls between option settings Button Decreases setting time temperature etc Scrolls between option settings 1 1 2 3 4 5 6 7 9 10 model 5400 shown with cover open 8 9 7 1 6 2 3 4 5 10 MODEL 5400 2008 Braeburn Systems LLC Patents Pending All Rights Reserved Pub N...

Page 2: ...SET 2 2 PROGRAMMING USER SETTINGS 2 3 Setting Thermostat System Selection The system can be selected by pressing the System button There are five possible settings to select from AUTO COOL OFF HEAT and EMER AUTO Auto can only be selected if it was enabled by the installer see Section 4 of the Installer Guide If AUTO is selected the system cycles between heating and cooling as determined by the set...

Page 3: ...n again and the LCD display will show d3 SET X where X equals the F C differential setting This is the current third stage differential setting 6 Press the or button to set the third stage differential to your desired setting of 1 2 3 4 5 or 6 F 0 5 1 0 1 5 2 0 2 5 or 3 0 C 4 2 PROGRAMMING USER SETTINGS cont 5 2 4 2 Setting the Filter Check Monitor see also section 3 7 The default setting is 0 day...

Page 4: ...e X is the temporary override limits 18 Press the or button to change the Temporary Override Time Limit to the desired value of 4 3 2 or 1 hour 2 4 8 Setting the Multi Level Keypad Lockout Code see section 3 10 19 Press and hold the RETURN button for four seconds Press RETURN button repeatedly until 000 SET LOCK is displayed 20 Press the or button to enter a 3 digit code using the RETURN button to...

Page 5: ...mming mode was selected during the Installer Setup Installer Guide the default program is the 2 events per day shown in the chart above Weekday Weekend MORN DAY EVE NIGHT Time 6 00 pm Heat 70 F 21 C Cool 75 F 24 C Time 8 00 am Heat 62 F 17 C Cool 83 F 28 C Time 6 00 am Heat 70 F 21 C Cool 75 F 24 C Time 10 00 pm Heat 62 F 17 C Cool 78 F 26 C 4 Event Time 6 00 pm Heat 70 F 21 C Cool 75 F 24 C Time ...

Page 6: ...le in auto changeover mode When you place the system in the HEAT or COOL modes of operation an appropriate indicator will appear in the LCD display when the system is running When you place the system in the OFF mode the display will indicate OFF NOTE If the PROG button is pressed while AUTO is selected the thermostat will switch from the AUTO mode to the mode currently in the display NOTE If Auto...

Page 7: ...utomatically 2 PROGRAMMING USER SETTINGS Entering Your Program 7 DAY Commercial Mode 1 Press the PROG button to enter the Program setting mode Press the SYSTEM button to select HEAT to set heating times and temperatures OCC occupied set point of the Whole Week will be displayed The display will show M TU W TH F SA SU to indicate the whole week is being programmed The hour portion of the set point ...

Page 8: ...r portion of the set point time and the AM PM indicator will be flashing 6 Follow steps 3 through 5 to set the set point times temperatures and fan mode for the periods of DAY EVE and NIGHT 2 PROGRAMMING USER SETTINGS cont 15 Entering Your Program 5 2 DAY Residential Mode continued 7 After pressing the PROG button you will enter the Weekend Program Group The display will show SA SU to indicate the...

Page 9: ...talled at setup the display temperature is either the temperature at the sensor or an average of the temperature at the sensor and the temperature at the thermostat 17 cont 3 ADDITIONAL OPERATION FEATURES 3 4 Remote Outdoor Sensor if installed The Braeburn Remote Outdoor Sensor is used for determining if balance points have been exceeded humidity control and for outdoor temperature display It is n...

Page 10: ...y See instructions provided with your UV source for recommendations on interval setting When the selected interval has been reached and required replacement has been performed press the RETURN button in any normal mode to reset the timer and turn off the warning 19 3 ADDITIONAL OPERATION FEATURES cont 3 9 Humidifier Pad Monitor see section 2 4 4 for setting The Humidifier Pad Monitor displays a re...

Page 11: ... used The proper operation of this function is preprogrammed into this thermostat No user changes are necessary 20 3 ADDITIONAL OPERATION FEATURES cont 3 11 Adaptive Recovery Mode ARM In order to maximize comfort and energy efficiency this thermostat is equipped with Adaptive Recovery Mode ARM This feature minimizes the amount of time required by the heating or cooling system to reach the new set ...

Page 12: ... Limits limit how much the thermostat can be adjusted from the program set points when the thermostat is used in the programmable mode This will not allow the user to set a temporary override in the heat or cool mode past the limit from the program set points The Temporary Override Adjustment Limits can only be used in the non programmable mode when the security level is at level 1 This will not a...

Page 13: ...m Fan continues to run in cooling mode when the system has turned off Potential Solution The Residual Cooling Fan Control Feature can allow up to a 90 second fan delay after cooling system shutdown for energy efficiency gains The default setting is 60 seconds This can be changed to disable this feature or shorten the time period if desired see section 4 of the Installer Guide Symptom Thermostat do...

Page 14: ...digit press the RETURN key for 1 second The display will return to the normal mode If an incorrect code is entered the display will flash no Symptom Keypad does not function Potential Solution Keypad is locked check for LOCK segment in display Symptom Thermostat will not follow program set points Potential Solutions Check current time of day day of week program settings Verify AM PM indicator is a...

Page 15: ... set point is limited Potential Solution Override limit was set in user options see section 2 4 7 Symptom Heating or cooling set point cannot be raised above a certain limit Potential Solution Set point limit was set in installer options Symptom Heating or cooling system turns on ahead of scheduled program times Potential Solution Adaptive recovery mode was enabled in installer options 5YEAR WARRA...

Reviews: