background image

5050

OWNERS MANUAL

Premier Series

7-Day Programmable

Single Stage Heat / Cool

Digital Thermostat

Compatible with low voltage single stage gas,

oil or electric heating or cooling systems,

including single stage heat pumps. This

thermostat can also be used on 250mv to

750mv millivolt heating only systems.

Do not use this thermostat on applications

with voltages above 30 Volts AC.

READ ALL INSTRUCTIONS BEFORE PROCEEDING

© 2004 Braeburn Systems LLC All Rights Reserved.

Pub. No. 5050-100-002

Store this

booklet for

future reference

Braeburn Systems LLC, as an Energy Star partner

has determined that this product meets the Energy

Star Guidelines developed by the U.S. Environmental

Protection Agency & the U.S. Department of Energy

for maximum energy efficiency.

WARRANTY

YEAR

LIMITED

CONTENTS

WARNING!

Quick Reference Contents Guide

Important Safety Information

FEATURES
SPECIFICATIONS
INSTALLATION

Replacing Existing Thermostat

Installing Your New Thermostat

TESTING YOUR NEW THERMOSTAT
PROGRAMMING

Default Thermostat Settings

Setting Current Time of Day and Day of Week

Setting Temperature Differential and Residual

Cooling Fan Feature

Setting Temperature Differential
Setting Residual Cooling Fan Feature

Setting Your Energy Saving Programs

Tips Before Starting
Using Quick Program Groups
or Individual Day Programming
Entering Your Program

ADDITIONAL OPERATION FEATURES

Review Set Temperature

Temporary Program Override

Permanent Hold (Vacation) Mode

High Temperature Safety Switch

Low Temperature "Freeze" Protection

Compressor Protection

Changing Fahrenheit (˚F) to Celsius (˚C)

Low Battery Detection and Replacement

Replacing the Batteries

Resetting Thermostat

TROUBLESHOOTING
WIRING DIAGRAMS

1

2

3

4
5

6

7
8

5.1

3.1
3.2

5.2
5.3

5.4

6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8

6.9

5.3

.1

5.3

.2

5.4

.1

5.4

.2

5.4

.3

6.8

.1

• Always turn off power to the air conditioning or heating system prior to installing,

removing, cleaning or servicing thermostat.

• Read this manual thoroughly prior to installing, programming or operating this

thermostat.

• This thermostat is designed for use with a 24 Volt AC low voltage single stage gas

oil or electric heating or cooling system. This thermostat can also be used on

250mv to 750mv millivolt heating only systems.

• Do not use this thermostat on applications with voltages higher than 30 Volts AC.

• This thermostat requires two (2) properly installed "AA" alkaline batteries to

provide power for the thermostat to properly control the system operation.

• The system must have 24 Volt AC power present for proper system operation and

control.

• Wiring must conform to all building codes and ordinances as required by local

and national code authorities having jurisdiction.

• Do not short (or jumper) across terminals on the gas valve or at the heating or

cooling system control board to test the thermostat installation. This could

damage the thermostat and void the warranty.

• Do not select

COOL

mode of operation if the outside temperature is below 50˚ F

(10˚ C). This could possibly damage the controlled cooling system and may cause

personal injury.

• This thermostat should only be used as described in this

manual. Any other use is not recommended and will void the warranty.

1

Summary of Contents for Premier 5050

Page 1: ...emperature Freeze Protection Compressor Protection Changing Fahrenheit F to Celsius C Low Battery Detection and Replacement Replacing the Batteries Resetting Thermostat TROUBLESHOOTING WIRING DIAGRAMS 1 2 3 4 5 6 7 8 5 1 3 1 3 2 5 2 5 3 5 4 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 5 3 1 5 3 2 5 4 1 5 4 2 5 4 3 6 8 1 Always turn off power to the air conditioning or heating system prior to installing rem...

Page 2: ...ng Control B B Reversing Valve Heating O O Reversing Valve Cooling C None Cap the Wire 24 Volt AC Transformer Common 3 3 INSTALLATION 4 After labeling and removing all wires from terminals unscrew the existing thermostat mounting base from wall Make sure to secure wires to prevent them from slipping back into the hole in the wall NOTE This thermostat is designed for use with a 24 Volt AC low volta...

Page 3: ...t Make sure to locate the positive ends of the batteries and match them with the positive terminals located in the battery compartment NOTE If you installed the batteries prior to accomplishing steps 14 thru 17 then you will need to reset the thermostat to register your thermostat switch configurations prior to programming Gently press the RESET button on the front of the thermostat using a paper ...

Page 4: ...current time of day note AM PM indicator in display and the current day of week correctly to avoid problems with program execution This must be done prior to entering any program settings Both the heating and cooling programs use the same setpoint times but allow different setpoint temperatures This thermostat is pre programmed with setpoint times and temperatures recommended by the U S Environmen...

Page 5: ...in flashing 6 Press the or buttons to change the setpoint temperature to the desired setting in 1 F increments 0 5 C press PROG button The thermostat will now display the DAY setpoint time and temperature Again you will see the hour portion of the setpoint time and the AM PM indicator will be flashing 7 Follow steps 4 through 6 to set the setpoint times and temperatures for the DAY EVE and NIGHT s...

Page 6: ...st be in the HEAT position for this feature to be active This feature will allow the thermostat to initiate a call for heat on standard heating non heat pump applications to provide a minimum amount of heat even if the batteries are dead or missing This feature is only active on standard heating non heat pump applications and is not available on single stage heat pump applications 11 NOTE Resettin...

Page 7: ...ressor short cycle protection 5 minute period expires the system should start within several seconds Low battery indicator is shown in thermostat display Replace batteries immediately to maintain proper system operation See Low Battery Detection and Replacement section of this manual OFF is shown in thermostat display and heating or cooling system will not start This indicates that the system is t...

Page 8: ...oling Fan Control Feature can allow up to a 90 second fan delay after cooling system shutdown for energy efficiency gains The default setting is 60 seconds This can be changed to disable this feature or shorten the time period if desired See Setting Residual Cooling Fan Feature section of this manual The room is too warm or too cold See Review Set Temperature section of this manual to verify the c...

Page 9: ...r liability does not apply to batteries nor does it include damage to merchandise or the thermostat resulting from accident alteration neglect misuse improper installation or any other failure to follow Braeburn installation and operating instructions Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our...