WIRING DIAGRAMS

8

cont.

Rc Rh

G

Remove

Factory Installed

Jumper

Typical 5-Wire Two Transformer Heating and Cooling System

W

Y

B

O

Heat

Control

Fan

Control

Cool

Control

Cool 24 VAC

Transformer

Heat 24 VAC

Transformer

120

Volt AC

120

Volt AC

Hot Side

Heat

Transformer

Hot Side

Cool

Transformer

Rc Rh

G

Factory Installed

Jumper

Typical Single Stage Heat Pump Reversing Valve Active in Cooling

W

Y

B

O

Fan

Control

Compressor

Control

Reversing

Valve

24 Volt AC

Transformer

120

Volt AC

Hot Side

Transformer

Rc Rh

G

Factory Installed

Jumper

Typical Single Stage Heat Pump Reversing Valve Active in Heating

W

Y

B

O

Fan

Control

Compressor

Control

Reversing

Valve

24 Volt AC

Transformer

120

Volt AC

Hot Side

Transformer

Braeburn Systems LLC warrants each new Braeburn thermostat

against any defects that are due to faulty material or

workmanship for a period of two years after the original date of

purchase by a professional service technician. This warranty

and our liability does not apply to batteries, nor does it include

damage to merchandise or the thermostat resulting from accident, alteration, neglect, misuse,

improper installation or any other failure to follow Braeburn installation and operating
instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat

under warranty provided it is returned postage prepaid to our warranty facility in a padded

carton within the warranty period, with proof of the original date of purchase and a brief

description of the malfunction. This limited warranty does not include the cost of removal or

re-installation.

WARRANTY

YEAR

LIMITED

This warranty gives you specific legal rights and you may also have other rights that vary from

state to state or province to province. Answers to any questions regarding our limited

warranty may be obtained by writing our corporate offices.

Braeburn Systems LLC

2215 Cornell Avenue • Montgomery, IL 60538

Technical Assistance: www.braeburnonline.com

866-268-5599

© 2004 Braeburn Systems LLC All Rights Reserved.

Warranty Facility:

Braeburn Systems LLC

Attn: Warranty Department

2215 Cornell Avenue

Montgomery, IL 60538

Summary of Contents for Premier 5050

Page 1: ...emperature Freeze Protection Compressor Protection Changing Fahrenheit F to Celsius C Low Battery Detection and Replacement Replacing the Batteries Resetting Thermostat TROUBLESHOOTING WIRING DIAGRAMS 1 2 3 4 5 6 7 8 5 1 3 1 3 2 5 2 5 3 5 4 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 5 3 1 5 3 2 5 4 1 5 4 2 5 4 3 6 8 1 Always turn off power to the air conditioning or heating system prior to installing rem...

Page 2: ...ng Control B B Reversing Valve Heating O O Reversing Valve Cooling C None Cap the Wire 24 Volt AC Transformer Common 3 3 INSTALLATION 4 After labeling and removing all wires from terminals unscrew the existing thermostat mounting base from wall Make sure to secure wires to prevent them from slipping back into the hole in the wall NOTE This thermostat is designed for use with a 24 Volt AC low volta...

Page 3: ...t Make sure to locate the positive ends of the batteries and match them with the positive terminals located in the battery compartment NOTE If you installed the batteries prior to accomplishing steps 14 thru 17 then you will need to reset the thermostat to register your thermostat switch configurations prior to programming Gently press the RESET button on the front of the thermostat using a paper ...

Page 4: ...current time of day note AM PM indicator in display and the current day of week correctly to avoid problems with program execution This must be done prior to entering any program settings Both the heating and cooling programs use the same setpoint times but allow different setpoint temperatures This thermostat is pre programmed with setpoint times and temperatures recommended by the U S Environmen...

Page 5: ...in flashing 6 Press the or buttons to change the setpoint temperature to the desired setting in 1 F increments 0 5 C press PROG button The thermostat will now display the DAY setpoint time and temperature Again you will see the hour portion of the setpoint time and the AM PM indicator will be flashing 7 Follow steps 4 through 6 to set the setpoint times and temperatures for the DAY EVE and NIGHT s...

Page 6: ...st be in the HEAT position for this feature to be active This feature will allow the thermostat to initiate a call for heat on standard heating non heat pump applications to provide a minimum amount of heat even if the batteries are dead or missing This feature is only active on standard heating non heat pump applications and is not available on single stage heat pump applications 11 NOTE Resettin...

Page 7: ...ressor short cycle protection 5 minute period expires the system should start within several seconds Low battery indicator is shown in thermostat display Replace batteries immediately to maintain proper system operation See Low Battery Detection and Replacement section of this manual OFF is shown in thermostat display and heating or cooling system will not start This indicates that the system is t...

Page 8: ...oling Fan Control Feature can allow up to a 90 second fan delay after cooling system shutdown for energy efficiency gains The default setting is 60 seconds This can be changed to disable this feature or shorten the time period if desired See Setting Residual Cooling Fan Feature section of this manual The room is too warm or too cold See Review Set Temperature section of this manual to verify the c...

Page 9: ...r liability does not apply to batteries nor does it include damage to merchandise or the thermostat resulting from accident alteration neglect misuse improper installation or any other failure to follow Braeburn installation and operating instructions Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our...

Reviews: