Identify System Type

This thermostat is compatible with the following systems:

• 

Gas, oil or electric furnace

• 

Central air conditioner

• 

Hot water system with or without pump

• 

Millivolt system

• 

Central heating and cooling system

• 

Heat pump without auxiliary/backup heat 

• 

Heat pump with auxiliary/backup heat

Do you need assistance? We are here to help.

Call 1-800-468-1502 for wiring assistance before returning 

the thermostat to the store.

This thermostat cannot be used on multistage systems.

Summary of Contents for RTH221B1021

Page 1: ...g systems Gas oil or electric furnace Central air conditioner Hot water system with or without pump Millivolt system Central heating and cooling system Heat pump without auxiliary backup heat Heat pump with auxiliary backup heat Do you need assistance We are here to help Call 1 800 468 1502 for wiring assistance before returning the thermostat to the store This thermostat cannot be used on multist...

Page 2: ...mostat containing mercury in the United States please refer to the Thermostat Recycling Corporation at www thermostat recycle org For mercury thermostat recycling in Canada please refer to Switch the Stat at www switchthestat ca NO MERCURY NO BOTE MERCURIO Hg RTHXXXX M32707 Customer assistance For assistance with this product please visit http yourhome honeywell com Or call Honeywell Customer Care...

Page 3: ...d operation Setting the clock 12 Adjusting program schedules 13 Overriding schedules temporarily 14 Overriding schedules permanently 14 Compressor protection 15 Early Start 15 Replace batteries 16 Appendices Troubleshooting 17 Limited warranty 18 Table of contents 1 Turn Off Power to Heating Cooling System or M31535 Circuit breaker box Heating cooling system power switch ...

Page 4: ...n If you have an older thermostat with a sealed mercury tube turn to page 2 for proper disposal instructions Terminal designation C C MCR31537 2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached 4 Separate Wallplate from New Thermostat Remove wallplate from the new thermostat and mount onto wall M32731 TO REMOVE WALLPLATE PULL HERE Wallplate ...

Page 5: ...bels If labels do not match letters on the thermostat check Alternate Wiring Conventional Systems on page 6 and connect to terminal as shown see notes below M32715 SCREW INSERT WIRES AND TIGHTEN SCREWS WIRE HOLE LABELED WIRES W Aux W Y G R Not Used Remove metal jumper if you have both R and Rc wires We are here to help Call 1 800 468 1502 for wiring assistance W Aux Not Used M32714 ...

Page 6: ...e end of wire with electrical tape If you have a heat pump without auxiliary backup heat connect O or B not both If you do not have a heat pump do not connect B Wrap bare end of wire with electrical tape Place a jumper piece of wire between Y and W if you are using a heat pump without auxiliary backup heat B O G Y W AUX NOT USED R Rc M32726 4 4 M32727 G W AUX O B Y Y G O R R Rc Aux Alternate Wirin...

Page 7: ...ified contractor for help If your old thermostat had separate O and B wires wrap the B wire in electrical tape and do not connect If your old thermostat had Y1 W1 and W2 wires stop now and contact a qualified contractor for help Do not use C or X wire Do not use B wire if you already have O wire Wrap bare end of wire with electrical tape Do not use L wire Wrap bare end of wire with electrical tape...

Page 8: ...heat systems This setting is for systems that allow the thermostat to control the fan in a call for heat if a fan wire is connected to the G terminal 9 Install Thermostat onto Wallplate Install thermostat onto the wallplate on the wall RTHXXXX M32716 GAS OR OIL ELECTRIC OR HEAT PUMP GAS OR OIL ELECTRIC OR HEAT PUMP 10Turn Power Back On Turn the power back on to the heating cooling system W Aux Not...

Page 9: ... of your system type or if you have other questions call us toll free at 1 800 468 1502 This thermostat works on 24 volt or 750 mV systems It will NOT work on multi stage conventional systems Advanced Installation Enter System Setup To enter system setup press and hold both the s and t buttons until the display changes approximately 5 seconds Changing Settings 1 Press the s or t button to change t...

Page 10: ... setting if you have a steam or gravity heat system 13 select Early Start 1 On 0 Off 14 select Fahrenheit or Celsius temperature display 0 Fahrenheit temperature display F 1 Celsius temperature display C 15 select Compressor Protection settings 1 On 0 Off 20 select clock display 0 12 hour display 1 24 hour display 40 restore program schedule to default settings 0 Off 1 On Program schedule default ...

Page 11: ...m Switch is used to control your heating or cooling system Heat Heating system control Off All systems off Cool Cooling system control Display screen M32701 We Lo Batt Wake Set am Heat 75 On 6 30 Low battery warning see page 16 Setpoint indicator Appears when the setpoint temperature is displayed Temperature The ambient measured temperature is normally displayed To view the setpoint temperature pr...

Page 12: ...d the pre set settings shown in the table below since they can reduce your heating cooling expenses Wake Set to the time you awaken and the temperature you want during the morning until you leave for the day Leave Set to the time you leave home and the temperature you want while you are away usually an energy saving level Return Set to the time you return home and the temperature you want during t...

Page 13: ...then press RUN to save exit NOTE Make sure the thermostat is set to the system you want to program Heat or Cool 1 Press SET until Set Schedule is displayed 2 Press s or t to set your Wake time for the day displayed then press SET 3 Press s or t to set the temperature for this time period then press SET 4 Set time and temperature for the next time period Leave Repeat steps 2 and 3 for each day s ti...

Page 14: ...t any time press RUN NOTE Make sure the thermostat is set to the system you want to control heat or cool Hold Set am 70 6 30 M32710 Set am 75 6 30 M32709 Program schedule override permanent Press HOLD to permanently adjust the temperature This will override the temperature settings for all time periods The Hold feature turns off the program schedule and allows you to adjust the thermostat manually...

Page 15: ...e a heat pump When the safe wait time has elapsed the message stops flashing and the compressor turns on We Wake am Cool 75 On 6 30 M32711 Early Start This feature allows the heating or cooling to turn on before the program start time so the temperature is reached at the time you set For example Set the Wake time to 6 am and the temperature to 70 The heat will come on before 6 am so the temperatur...

Page 16: ...d in non volatile permanent memory Only the clock and the day must be set after you replace the batteries Pull at bottom to remove thermostat from wallplate Turn thermostat over insert fresh AAA alkaline batteries then reinstall thermostat Set the System switch to Off before removing the batteries Otherwise the heating cooling system could remain activated even when batteries are removed RTHXXXX M...

Page 17: ...et lower than the Inside temperature Wait 5 minutes for the system to respond Temperature settings do not change Make sure heating and cooling temperatures are set to acceptable ranges Heat 40 to 90 F 4 5 to 32 C Cool 50 to 99 F 10 to 37 C Cool On or Heat On is flashing Compressor protection feature is engaged Wait 5 minutes for the system to restart safely without damage to the compressor Heat On...

Page 18: ...stallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQU...

Page 19: ... Calefactor a gas aceite o eléctrico Aire acondicionado central Sistema a agua caliente con o sin bomba Sistema de milivoltios Calefacción y aire acondicionado centrales Bomba de calor sin calefacción auxiliar Bomba de calor con calefacción auxiliar Necesita ayuda Aquí estamos Llame al 1 800 468 1502 para obtener asistencia con el cableado antes de devolver el termostato a la tienda Este termostat...

Page 20: ...n termostato que contenga mercurio en los Estados Unidos consulte con Thermostat Recycling Corporation en www thermostat recycle org Para el reciclaje de termostatos con mercurio en Canadá consulte con Switch the Stat en www switchthestat ca NO MERCURY NO BOTE MERCURIO Hg RTHXXXX M32707 Asistencia al cliente Para obtener asistencia relacionada con este producto visite http yourhome honeywell com O...

Page 21: ... Ajuste de los cronogramas del programa 13 Anulación temporal de los cronogramas 14 Anulación permanente de los cronogramas 14 Protección del compresor 15 Arranque anticipado 15 Reemplazo de la batería 16 Apéndices Localización y solución de problemas 17 Garantía limitada 18 Índice 1 Desconecte la alimentación en el sistema de calefacción refrigeración o M31535 Caja de interruptores de circuito In...

Page 22: ...les Si el termostato existente tiene un tubo de mercurio sellado vaya a la página 2 para obtener instrucciones sobre cómo desecharlo adecuadamente Rótulos para los cables Designación de los terminales C C MCR31537 3 Identifique los cables Identifique los cables a medida que los desconecta utilizando las etiquetas que se suministran 4 Separe la placa de montaje del termostato nuevo Retire la placa ...

Page 23: ...os cables Si las etiquetas no corresponden con las letras del termostato revise Conexión alternativa Sistema convencional en la página 6 y conecte al terminal como se indica refiérase a las notas que siguen Retire el empalme metálico si tiene los cables R y Rc MS32715 TORNILLO INSERTE LOS CABLES YAPRIETE LOS TORNILLOS ORIFICIO DE CABLEADO CABLES ETIQUETADOS W Aux W Y G R Not Used Estamos aquí para...

Page 24: ... con cinta aislante Si tiene una bomba de calor sin calefacción auxiliar de reserva conecte O o B no ambos Si no tiene una bomba de calor no conecte B Envuelva los extremos pelados del cable con cinta aislante Coloque un puente trozo de cable entre Y y W Aux si está utilizando una bomba de calor sin calefacción auxiliar de reserva B O G Y W AUX NOT USED R Rc MS32726 4 4 No Conecte M32727 G W AUX O...

Page 25: ...hora pare y entre en contacto con un contratista para la ayuda Si su termostato existente tenía cables O y B separados envuelva el cable B en cinta aislante y no lo conecte Si su termostato existente tenía cables Y1 W1 y W2 ahora pare y entre en contacto con un contratista para la ayuda No usar los cables C o X no usar el cable b si ya hay un cable O envolver el extremo desnudo con cinta aisladora...

Page 26: ...a Esta configuración es para sistemas que permitan que el termostato controle el ventilador en una orden de calefacción si un cable del ventilador está conectado al terminal G 9 Instale el termostato en la placa de montaje Instale el termostato en la placa de montaje en la pared RTHXXXX M32716 GAS OR OIL ELECTRIC OR HEAT PUMP GAS OR OIL ELECTRIC OR HEAT PUMP 10Active nuevamente el suministro eléct...

Page 27: ... tiene otras preguntas llámenos gratis al 1 800 468 1502 Este termostato funciona con sistemas de 24 voltios o 750 mV NO funcionará con sistemas convencionales de etapas múltiples ni con sistemas de 120 240 voltios Guía de instalación avanzada Ingrese la configuración del sistema Para ingresar la configuración del sistema presione y mantenga presionados los botones s arriba y t abajo hasta que el ...

Page 28: ...seleccione Encendido anticipado 1 Encendido 0 Apagado 14 elegir el indicador de temperatura en grados Fahrenheit o Centígrados 0 Indicador de temperatura en grados Fahrenheit F 1 Indicador de temperatura en grados Centígrados C 15 elegir la configuración de protección del compresor 1 Encendido 0 Apagado 20 elegir el visualizador del reloj 0 Visualizador de 12 horas 1 Visualizador de 24 horas 40 re...

Page 29: ...tablecer Presione para volver al cronograma del programa Pantalla de visualización M32701 We Lo Batt Wake Set am Heat 75 On 6 30 Aviso de batería baja vea la página 16 Estado del sistema Cool on frío encendido El sistema de refrigeración está encendido Heat on calor encendido El sistema de calefacción está encendido Cuando Cool On parpadean la protección del compresor está activada ver la página 1...

Page 30: ...as se muestran en el cuadro a continuación debido a que reducen los gastos de calefacción y refrigeración WAKE Programe la hora en que se despierta y la temperatura que quiere durante la mañana hasta que usted se va de su casa LEAVE Programe la hora en que usted se va de su casa y la temperatura que quiere mientras no esté en su casa por lo general un nivel de ahorro de energía RETURN Programe la ...

Page 31: ... Para ajustar los cronogramas del programa RTHL2410 1 Presione SET configurar hasta que Set Schedule configurar el cronograma se muestre en la pantalla 2 Presione s o t para configurar la hora en que se despierta los días de la semana de lunes a viernes y luego presione SET 3 Presione s o t para configurar la temperatura para este período y luego presione SET 4 Configure la hora y la temperatura p...

Page 32: ...istema que usted quiere controlar calor o frío Temporary Wake Set am 70 6 30 M32708 Set am 75 6 30 M32709 Hold Set am 70 6 30 M32710 Set am 75 6 30 M32709 Programación de la anulación del cronograma permanente Presione HOLD para ajustar permanentemente la temperatura Esto anulará las configuraciones de la temperatura para todos los períodos La función Hold apaga el cronograma del programa y le per...

Page 33: ...rrido el tiempo de espera de seguridad el mensaje dejará de titilar y se encenderá el compresor We Wake am Cool 75 On 6 30 M32711 Esta característica permite que se active la calefacción o refrigeración antes de la hora de inicio del programa para que alcance la temperatura a la hora que usted configuró Por ejemplo configure la hora para despertarse a las 6 a m y la temperatura a 70 F 21 1 C La ca...

Page 34: ...permanecer activado aun cuando se hayan sacado las baterías RTHXXXX M32707 W Aux Not Used Heat Off Cool Auto On Fan M32705 Instale dos pilas AAA nuevas cuando Lo Batt parpadee en la pantalla El icono aparecerá 60 días antes de que las pilas estén completamente descargadas Reemplace las pilas una vez por año o luego de una ausencia de más de un mes La mayor parte de los datos de la configuración es...

Page 35: ...ea más baja que la temperatura interna Espere 5 minutos para que responda el sistema Las configuraciones de la temperatura no cambian Asegúrese de que las temperaturas de calor y frío estén configuradas en rangos aceptables Heat De 40 F a 90 F de 4 5 C a 32 C Cool De 50 F a 99 F de 10 C a 37 C El mensaje Cool On o Heat On titila La función de la protección del compresor está funcionando Espere 5 m...

Page 36: ...licará si Honeywell demuestra que el defecto o mal funcionamiento estaba causado por daños ocurridos mientras el producto estaba en posesión de un consumidor La única responsabilidad de Honeywell será reparar o reemplazar el producto dentro de los plazos establecidos anteriormente HONEYWELL NO RESPONDERA POR LA PÉRDIDA O DAÑO DE NINGUN TIPO INCLUIDO EL DAÑO INCIDENTAL O INDIRECTO DERIVADO DIRECTA ...

Reviews: