background image

• Audio/data connection line: non polarized twi-

sted pair Z = 100 

.

• Working temperature range: 0 °C to +35 °C.

Installing handset module XC/310

Having removed the casing (front screw in fig. 5,
bottom) and receiver, fasten the housing directly
to the wall (fig. 6A) or to the embedding box (fig.
6B or 6C).
If walls are not perfectly flat, take care not to
overtighten screws. Perform the wiring. Refit its
casing and apply the two sides (fig. 7 and 8).
Insert the receiver’s cable connector in the hou-
sing and hang up the receiver (fig. 8).
The handset features a name card on which you
can write relevant data. Remove the glass cover
to insert the name card (fig. 8).

WARNING. In installations with XA/300LR we
recommend you gather up the ID (SN) codes,
applied on the outside of the housing, and enter
them in the tables that come with the XA/300LR,
MPP/300LR and IPC/300LR.

XV/200(XVC/200)+XC/310 
INTERCOM VIDEO HANDSET

Internal unit with video and secrecy of speech.
With this apparatus, the video signal may be
transmitted by either a coaxial or a twisted pair. 
Can be either wall or table-top versions using
the relevant mounting.

XV/200 MONITOR MODULE

It is equipped with the following controls (fig. 3):

Entry panel activation/selection (

1

)

Centralized control (stair light or other ser-
vices) (

2

Contrast

Brightness

XVC/200 COLOUR MONITOR MODULE

It is equipped with the following controls (fig. 4):

Entry panel activation/selection (

1

)

Centralized control (stair light or other ser-
vices) (

2

Saturation colour

Brightness

(

1

) The activation of the video handset and its

subsequent connection to the external entry
panel, are only possible if the system is not
engaged by other conversations.
(

2

) This control can normally only be used with

the monitor on. Should the user want to be able
to use this control even when the monitor is off,
power supplier XA/300LR must be programmed
with unit MPP/300LR.

WARNINGS FOR THE USER
- Please do not open or tamper the device
(high voltage!).
- Please avoid knocking or bumping the appa-
ratus as it could result in the breakage of the
picture tube and the consequent projection
of glass fragments.
- In the case of breakdown or modification of
the apparatus of the system (such as power
supplier ...) please contact a specialized
maintenance service.
- To clean the apparatus use a soft cloth or
buckskin. Do not use liquids containing
alcohol or ammonia.

NOTE. In the event a call is made from the entry
panel, the selection in progress is interrupted.

3

INTERCOM HANDSET MODULE XC/310

Intercom receiver compatible with the X2 TECH-
NOLOGY system and system 300.
Using this unit, intercom installations with up to
10 units can be set up. By means of selector
VSE/300, secrecy of speech during conversa-
tions is assured.
It can store up to 3 numbers for calls from entry
panels. In video entry control installations, it can
control the video module and manage auxiliary
2 and self-connection for entrance monitoring
controls.
The unit can be connected directly to the audio
or video entry control installation and can use
intercom call buttons as auxiliary service con-
trols. Calls from the entry panel can be indivi-
dual, for a single group or for all receivers asso-
ciated with the same VSE/300.
It features a 

CNH

connector (fig. 2) for connec-

tion to wall mounting XKP/300.
It features the following controls (fig. 1):

1÷5

Call buttons

Doubling button (for calls 6-10)

Auxiliary services/porter call

Door lock release (

1

)

(

1

) This control can only be used if the unit is on

.

NOTE. The LED lights to advise the user that the
doubling function is enabled, whilst the same
LED flashes once the receiver is lifted to report
line busy status where a conversation between
receivers is already in progress.

Call transfer

During a conversation between receivers, an
acoustic warning sounds to advise the occupant
that there is a call from the entry panel.
Pressing one of the call buttons and replacing
the receiver transfers the conversation to a diffe-
rent receiver.
The unit receiving the transferred call can, in
turn, retransfer it to another.

Function of each terminal
Terminal block M1

B

line

personal door-bell

ground

call repeater  

Function of jumper SW1

The unit usually comes with the jumper inserted.
Remove the jumper if you want to attenuate call
note volume (fig. 2).

Personal door-bell button

The video handset is fitted with a differentiated
call input (terminal 

) (i.e.: for calls from landing

and external entry panel) a continuous tone call
(approximately 2 s).

Programming

To programme calls in system 300 or X2 TECH-
NOLOGY system installations, see the literature
supplied with the units.
To  programme intercom calls, see the instruc-
tions supplied with selector VSE/300.

Technical features

• Power supply: from data line itself.
• Current demand: < 5 mA with LED on.

GB

INSTRUCTIONS FOR USE
AND INSTALLATION

5/10

4/9

3/8

2/7

1/6

4

XVC/200+XC/310

2

1

5

6A

Summary of Contents for XC/310

Page 1: ...TENZE PER L INSTALLATORE Queste istruzioni devono essere allegate al derivato interno WARNING FOR THE INSTALLER These instructions should be attached to the receiver ACHTUNG NUR FÜR INSTALLATEUR Diese Anleitungen müßen jede Sprechstelle begleiten PRECAUTIONS POUR L INSTALLATEUR Cettes instructions doivent accompagner chaque poste intérieur ADVERTENCIAS PARA EL INSTALADOR Estas instrucciones se deb...

Page 2: ... 10 4 9 3 8 2 7 1 6 Linea di collegamento audio dati doppino non polarizzato Z 100 Ω Temperatura di funzionamento da 0 C a 35 C Installazione del modulo citofono XC 310 Dopo aver tolto il mobile vite frontale di fig 5 in basso e la cornetta fissare la base direttamen te al muro fig 6A oppure alla scatola incasso fig 6B o 6C Su pareti non perfettamente piane evitare il serraggio eccessivo delle vit...

Page 3: ... containing alcohol or ammonia NOTE In the event a call is made from the entry panel the selection in progress is interrupted 3 INTERCOM HANDSET MODULE XC 310 Intercom receiver compatible with the X2 TECH NOLOGY system and system 300 Using this unit intercom installations with up to 10 units can be set up By means of selector VSE 300 secrecy of speech during conversa tions is assured It can store ...

Page 4: ...h bei ausgeschaltetem Monitor verwenden möchte ist die Programmie 4 83 5 mm 6B 60 mm 6C 1 2 7 1 2 3 5 4 8 INTERCOM SPRECHMODUL XC 310 Eine mit dem System X2 TECHNOLOGY und dem System 300 kompatible Intercom Innensprechstelle Durch dieses Gerät sind Intercom Anlagen mit bis zu 10 Einheiten zusammenstellbar der Wählschalter VSE 300 ermöglicht eine Mithörsperre Kann bis zu 3 Rufnummern der Außenstati...

Page 5: ...ra turen an den Geräten Netzgerät usw wen den Sie sich bitte nur an einen Spezialisten Zur Reinigung des Gerätes ist ein leichtes Tuch am besten Leder zu benutzen Dabei ist die Anwendung von alkohol oder ammoniakhaltigen Reinigungsmitteln auszu schliessen Einbau des Sprechmoduls XC 310 mit dem Videomodul XV 200 XVC 200 Für den Einbau siehe Anleitungen der Wandhalterung XKP 300 Fonction des bornes ...

Page 6: ...s posible utilizar este comando sólo si el aparato está activo NOTA La función de duplicación queda señala da por el encendido del LED mientras que la línea ocupada en caso de conversación interna queda señalada por la intermitencia del mismo LED tras levantar el auricular Transferencia de llamada Durante una conversación interna una eventual llamada desde la placa exterior es señalada al telefono...

Page 7: ...el transferir a conversação de um a outro derivado interno O derivado que recebeu a chamada transferida pode por sua vez tornar a transferir de novo a chamada Função dos bornes Placa de bornes M1 B linha chamada do patamar massa repetidor de chamada Função da ponte SW1 Normalmente é fornecida inserida Tirar a ponte se por acaso se quiser atenuar o volume da nota de chamada fig 2 Chamada do patamar...

Page 8: ...8 ...