• Audio/data connection line: non polarized twi-
sted pair Z = 100
Ω
.
• Working temperature range: 0 °C to +35 °C.
Installing handset module XC/310
Having removed the casing (front screw in fig. 5,
bottom) and receiver, fasten the housing directly
to the wall (fig. 6A) or to the embedding box (fig.
6B or 6C).
If walls are not perfectly flat, take care not to
overtighten screws. Perform the wiring. Refit its
casing and apply the two sides (fig. 7 and 8).
Insert the receiver’s cable connector in the hou-
sing and hang up the receiver (fig. 8).
The handset features a name card on which you
can write relevant data. Remove the glass cover
to insert the name card (fig. 8).
WARNING. In installations with XA/300LR we
recommend you gather up the ID (SN) codes,
applied on the outside of the housing, and enter
them in the tables that come with the XA/300LR,
MPP/300LR and IPC/300LR.
XV/200(XVC/200)+XC/310
INTERCOM VIDEO HANDSET
Internal unit with video and secrecy of speech.
With this apparatus, the video signal may be
transmitted by either a coaxial or a twisted pair.
Can be either wall or table-top versions using
the relevant mounting.
XV/200 MONITOR MODULE
It is equipped with the following controls (fig. 3):
Entry panel activation/selection (
1
)
•
Centralized control (stair light or other ser-
vices) (
2
)
Contrast
Brightness
XVC/200 COLOUR MONITOR MODULE
It is equipped with the following controls (fig. 4):
Entry panel activation/selection (
1
)
•
Centralized control (stair light or other ser-
vices) (
2
)
Saturation colour
Brightness
(
1
) The activation of the video handset and its
subsequent connection to the external entry
panel, are only possible if the system is not
engaged by other conversations.
(
2
) This control can normally only be used with
the monitor on. Should the user want to be able
to use this control even when the monitor is off,
power supplier XA/300LR must be programmed
with unit MPP/300LR.
WARNINGS FOR THE USER
- Please do not open or tamper the device
(high voltage!).
- Please avoid knocking or bumping the appa-
ratus as it could result in the breakage of the
picture tube and the consequent projection
of glass fragments.
- In the case of breakdown or modification of
the apparatus of the system (such as power
supplier ...) please contact a specialized
maintenance service.
- To clean the apparatus use a soft cloth or
buckskin. Do not use liquids containing
alcohol or ammonia.
NOTE. In the event a call is made from the entry
panel, the selection in progress is interrupted.
3
INTERCOM HANDSET MODULE XC/310
Intercom receiver compatible with the X2 TECH-
NOLOGY system and system 300.
Using this unit, intercom installations with up to
10 units can be set up. By means of selector
VSE/300, secrecy of speech during conversa-
tions is assured.
It can store up to 3 numbers for calls from entry
panels. In video entry control installations, it can
control the video module and manage auxiliary
2 and self-connection for entrance monitoring
controls.
The unit can be connected directly to the audio
or video entry control installation and can use
intercom call buttons as auxiliary service con-
trols. Calls from the entry panel can be indivi-
dual, for a single group or for all receivers asso-
ciated with the same VSE/300.
It features a
CNH
connector (fig. 2) for connec-
tion to wall mounting XKP/300.
It features the following controls (fig. 1):
1÷5
Call buttons
Doubling button (for calls 6-10)
•
Auxiliary services/porter call
•
Door lock release (
1
)
(
1
) This control can only be used if the unit is on
.
NOTE. The LED lights to advise the user that the
doubling function is enabled, whilst the same
LED flashes once the receiver is lifted to report
line busy status where a conversation between
receivers is already in progress.
Call transfer
During a conversation between receivers, an
acoustic warning sounds to advise the occupant
that there is a call from the entry panel.
Pressing one of the call buttons and replacing
the receiver transfers the conversation to a diffe-
rent receiver.
The unit receiving the transferred call can, in
turn, retransfer it to another.
Function of each terminal
Terminal block M1
B
line
personal door-bell
–
ground
call repeater
Function of jumper SW1
The unit usually comes with the jumper inserted.
Remove the jumper if you want to attenuate call
note volume (fig. 2).
Personal door-bell button
The video handset is fitted with a differentiated
call input (terminal
) (i.e.: for calls from landing
and external entry panel) a continuous tone call
(approximately 2 s).
Programming
To programme calls in system 300 or X2 TECH-
NOLOGY system installations, see the literature
supplied with the units.
To programme intercom calls, see the instruc-
tions supplied with selector VSE/300.
Technical features
• Power supply: from data line itself.
• Current demand: < 5 mA with LED on.