26
Cleaning, maintenance and repair
Jelly Mini Boy - Digital Airmix Edition 12.08
5.1.1
Cleaning the air- and agent-nozzle
- Close the ball valve on the compressed air
connection. Refer to chapter "Connecting the
implement to an external compressed air source",
page 16.
- Pull the bleed valve until the hissing noise stops.
Refer to chapter "Filling the storage tank", page
15.
- Actuate the spray gun and thus discharge the
residual air pressure out off the system.
- Manually slacken the collar nut (1) and remove.
- Remove the air-nozzle (2) from the spray gun.
- Unscrew the agent-nozzle (3) from the connection
piece (4) with the special wrench supplied and
remove.
Only use the special wrench supplied to
unscrew and tighten the agent-nozzle.
- Clean the air-nozzle and the agent-nozzle using
hot water.
- Blow out the agent-nozzle with compressed air or
with the mouth against the direction of flow.
By holding the agent-nozzle up to the
light, check whether there are still any
particles inside the agent-nozzle.
- Screw the agent-nozzle (3) back onto the
connection piece.
- Firmly retighten the agent-nozzle with the special
wrench supplied.
- Screw the air-nozzle back on and tighten by hand.
- Replace the spray gun in its retainer.