Putting into operation
15
Jelly Mini Boy - Digital Airmix Edition 12.08
4.4
Filling the storage tank
Always pull the bleed valve (1) until the
excess pressure has been completely
discharged from the storage tank (2). If
the hissing noise stops, the storage tank
has been depressurised and you can
open the storage tank cover.
Only open the storage tank cover (3)
after the agent boiler has been
depressurised! Danger of injury from
discharging hot agent!
- Close the ball valve on the compressed air
connection. Refer to chapter "Connecting the
implement to an external compressed air source",
page 16.
- Pull the bleed valve (1), until the hissing noise
stops.
- Swing the storage tank cover closure (4) into the
unlocking position (5).
- Open the storage tank cover (3).
- Fill the agent to be processed that has been
heated externally into the storage tank via the
storage tank opening (6).
The agent to be processed must be
externally warmed up to processing
temperature.
free of lumps.
free of foreign objects.
If the agent is not free of lumps or free of
foreign objects, the agent nozzle in the
spray gun will choke.
- Clean the seal on the storage tank cover (7).
- Reseal the storage tank with the storage tank
cover (3).
- Swing the storage tank cover closure (4) into the
locking position (8).
- Check whether the bleed valve (1) is closed.
- Open the ball valve on the compressed air supply.
Summary of Contents for Jelly Mini Boy Digital Airmix
Page 38: ...38 Circuit diagrams Jelly Mini Boy Digital Airmix Edition 12 08 7 Circuit diagrams...
Page 39: ...Circuit diagrams 39 Jelly Mini Boy Digital Airmix Edition 12 08...
Page 40: ...40 Circuit diagrams Jelly Mini Boy Digital Airmix Edition 12 08...
Page 41: ...Circuit diagrams 41 Jelly Mini Boy Digital Airmix Edition 12 08...