32
Cleaning, maintenance and repair
Jelly Mini Boy - Digital Airmix Edition 12.08
5.9 Trouble
shooting
Fault Cause
Remedy
No temperature display
Electric power supply interrupted
- Check whether the implement
has been switched on.
- Check whether the electric
power supply has been
interrupted.
Implement not switched on
- Switch on the implement.
The processing temperature had
been set too low
- Correctly set the processing
temperature, refer to page 19.
Safety switch activated
- Let the implement cool down for
approx. 1 hour.
- Remove the black cap.
- Press in the switch.
Temperature control defect
- Contact the maintenance
service.
Temperature does not rise
Microprocessor defective
- Contact the maintenance
service.
The processing temperature had
been set too high
- Set the processing temperature,
refer to page 18.
Temperature control defect
- Contact the maintenance
service.
Temperature too high
Microprocessor defective
- Contact the maintenance
service.
Leaks
- Check all visible connections.
Seal of the storage tank cover
leaking
- Repair the leaking seal of the
storage tank cover, refer to
page 29.
Storage tank cover seal wore or is
missing
- Replace the storage tank cover
seal, refer to page 29.
Agent pressure is constantly
dropping
Bleed valve defect
- Replace the bleed valve.
Summary of Contents for Jelly Mini Boy Digital Airmix
Page 38: ...38 Circuit diagrams Jelly Mini Boy Digital Airmix Edition 12 08 7 Circuit diagrams...
Page 39: ...Circuit diagrams 39 Jelly Mini Boy Digital Airmix Edition 12 08...
Page 40: ...40 Circuit diagrams Jelly Mini Boy Digital Airmix Edition 12 08...
Page 41: ...Circuit diagrams 41 Jelly Mini Boy Digital Airmix Edition 12 08...