21
SPOOL
GUN
1
2
3
4
7
8
6
PANEL DESCRIPTION
1.
Down Slope / Hydro-cooling Parameter Code Display.
2.
Welding Current. / Down Slope Time / Hydro-cooling ON/OFF Display
3.
Welding Current Indicator Light
4.
TIG Function Select.
5.
2T / 4T Trigger Select.
6.
Down Slope / Hydro-cooling Parameter Select press to Enter and Exit.
7.
Down Slope / Hydro-cooling Code Select turn Knob Left or Right.
8.
Welding Current. / Down Slope Time / Hydro-cooling, Turn Knob Left or Right to set to desired setting.
Set up installation for DC TIG Welding
1. Insert the earth cable plug into the positive socket on the front of the machine and tighten it.
2. Plug the TIG torch into the negative socket on the front panel, and tighten it.
3. Connect the gas line of TIG Gun to outlet gas connector on the front of the machine . Check for Leaks!
4. Connect the control cable of torch switch to 9 pin socket on the front of the machine ..
5. Connect the gas regulator to the Gas Cylinder and connect the gas line to the Gas Regulator. Check for Leaks!
6. Connect the gas line to the machine inlet gas connector via the quick push lock connector located on the rear panel.
Check for Leaks!
7. Connect the power cable of welding machine with the output switch in electric box on site
8. Carefully open the valve of the gas cylinder, set the required gas flow rate.
9. Select TIG function on the front panel.
10. Set torch operation 2T / 4T.
- When 2T operation is selected press trigger Gas starts, touch and lift arc start, release trigger Gas and Arc stops.
- When 4T operation is selected press and release trigger Gas starts, touch and lift arc start, press and release trigger
Gas and Arc stops.
TIG FUNCTION - FRONT PANEL DESCRIPTION
5
IMPORTANT! -
We strongly recommend that you check for gas leakage prior to operation of your machine.
We recommend that you close the cylinder valve when the machine is not in use.
BOSSWELD authorised representatives or agents of BOSSWELD will not be liable or responsible for the
loss of any gas.