19
PROGRAM
NUMBER
WIRE TYPE
WIRE
Ф (mm)
MATERIAL THICKNESS
(mm)
GAS
P1
Solid Fe
0.8
1.0 > 4.0
CO
2
P2
Solid Fe
0.8
0.9 > 4.7
80%Ar+20%CO
2
P3
Solid Fe
0.9
1.3 > 5.1
CO
2
P4
Solid Fe
0.9
0.7 > 3.8
80%Ar+20%CO
2
P5
Solid Fe
1
0.9 > 5.8
80%Ar+20%CO
2
P6
Solid Fe
1
1.2 > 9.1
CO
2
P7
Solid Fe
1.2
1.3 > 7.2
CO
2
P8
Solid Fe
1.2
1.1 > 5.0
80%Ar+20%CO
2
P9
Flux.c.w Fe
1
1.1 > 8.0
CO
2
P10
Flux.c.w Fe
1.2
1.1 > 8.0
CO
2
P11
SS ER316
1
1.1 > 5.8
98%Ar+2%CO
2
P12
SS ER316
1.2
1.9 > 12.0
98%Ar+2%CO
2
P13
Cu Si3
1
0.7 > 4.3
Ar100%
P14
Cu Si3
1.2
1.1 >3.3
Ar100%
PROGRAM
NUMBER
WIRE TYPE
WIRE
Ф (mm)
MATERIAL THICKNESS
(mm)
GAS
P1
AlMg5
0.9
0.8 > 6.0
Ar100%
P2
AlMg5
1
1.0 > 8.0
Ar100%
P3
AlMg5
1.2
0.7 > 11.0
Ar100%
P4
AlSi5
1
0.7 > 7.8
Ar100%
P5
AlSi5
1.2
0.8 > 8.0
Ar100%
P6
Al99.5
1.2
0.7 > 8.8
Ar100%
P7
Fe
0.8
0.8 > 6.4
80%Ar+20%CO
2
P8
Fe
0.9
1.3 > 9.7
80%Ar+20%CO
2
P9
Fe
1
0.8 > 8.6
80%Ar+20%CO
2
P10
Fe
1.2
1.0 > 7.1
80%Ar+20%CO
2
P11
SS ER316
1
1.0 > 8.5
98%Ar+2%CO
2
P12
SS ER316
1.2
1.1 > 7.8
98%Ar+2%CO
2
P13
Flux.c.w Fe
1.2
2.6 > 11.2
80%Ar+20%CO
2
P14
Flux.c.w SS
1.2
1.9 > 17.4
80%Ar+20%CO
2
P15
CuSi3
1
0.8 > 8.9
Ar100%
P16
CuSi3
1.2
1.1 > 8.9
Ar100%
P17
CuAl8
1.2
1.1 > 8.9
Ar100%
Synergic Dual Pulse Parameter
Synergic MIG Parameter
Dual pulse function introduction
Dual pulse welding in single pulse welding with low frequency modulated pulse, low frequency pulse frequency
0.5-3.0Hz. Single pulse compared to dual pulse has the advantages of: without welding swing, weld automatic fish
squamous and fish scale pattern density, the depth can be adjusted; to be more precise control of heat input. During the
low current, cooling the molten pool, reduce workpiece deformation, reduce the hot cracking tendency; and periodically
stirring molten pool, grain refinement, the hydrogen gas from the molten pool in precipitation to reduce the porosity and
reduce welding defects. Dual pulse reference waveform as shown below:
DUAL PULSE FREQUENCY
Set low frequency pulse frequency, as shown in Figure regulating the value of time T, namely, fish scale pattern of
density regulation.
DUAL PULSE DUTY
Dual pulse duty set strong pulse group time T1 and low-frequency cycle T ratio, namely the regulation of the proportion of
the fish scale pattern in the protruding part and the groove.
Wire feed
Current