PRE GAS
Selection for gas flow time prior to the arc starting
Adjustable from 0 - 5 sec
POST GAS
Selection for gas flow time after the arc finishes.
Adjustable from 0 - 10 sec
SLOW FEED TIME
Used to regulate the speed of wire feeding increasing.
Adjustable from 0 - 10 sec
BURNBACK
Control sets the amount of wire to ‘burn back’ after you release the trigger
of your torch.
Adjustable from 0 - 10
SPOT WELD TIME
List the time during which welding current is applied to the metal sheets
Adjustable from 0 - 10 sec
DELTA PULSE CURRENT
The difference between base current and peak current in pulse welding.
Adjustable from 20-200Amps
DUAL PULSE FREQUENCY
Set pulse frequency, regulating the value of time T, ripple pattern of
density regulation.
Adjustable from 0.5 - 3.0Hz
DUAL PULSE DUTY
Set strong pulse time (peak) for penetration and low-frequency
cycle ratio (cooling)
Adjustable from 10 - 90%
DUAL PULSE BASE CURRENT PERCENT
Sets the current of the low/ base pulse.