To ensure the safety of the person and the equipment, please follow the instructions
on the equipment and all the safety precautions described in the manual when
operating and maintaining the equipment. The "Safety Warnings," Cautions" and
"Description
s
" matter in the manual do no
t
represent all the safety matters that
should be followed and only as a supplement to all safety precautions.
Observe All Safety Precautions
Comply with Local Regulations and Regulations
When operating the equipment, observe local regulations and specifications.
Personnel Requirements
Personnel responsible for the maintenance and operation of the equipment must
be read and operated with the necessary information and safety precautions
before operating and maintaining the equipment.
Daily Maintenance
•
Regularly check the coaxial cable connection (for tightness) between the
capacitive sensing element (nozzle) and the FTC. If it's loosen or not tight, it
should be tighten, otherwise it will affect the measurement results.
•
Regularly check the capacitance sensor (nozzle) oxidation and wear. Severe
oxidation or wear should be replaced promptly, otherwise it will affect the
measurement results.
•
Regularly check the status of the FTC indicator. If the ALM light is lit, it
indicates that the FTC part has failed.
•
Regularly do the floating head calibration once a day.
FTC61 SERIES MANUAL
Document Number: 855-910
Revision: 001
Revision Date: 6/1/2019
BOSSLASER - PAGE 10 of 12