Input Signal Detection Function
For closer cooperation with the laser system, the FTC61 extends the 6-way dry contact signal
input detection while completing the closed-loop control. It can be used for signal detection such
as calibration (CA) / perforation (BH), follow (TR), move up (ZUP), move down (ZDN), upper
limit (UL), and lower limit (LL).
Switch Signal Detection Parameters
•
Calibration (CA) / Perforation (BH):
Dry contact input signal, connected to valid
o
Enter the dry contact signal
o
Calibration Signal ON:
Starts the floating head calibration.
o
Punching Signal ON:
Start punching
o
Break:
Stop perforation.
o
This signal needs to be turned on before the following signal
•
Follow (TR):
Dry contact input signal, connected to valid
o
When there is a follower signal, control the cutting head to reach the following
height. Disconnect stops and returns to the wait bit.
•
Movable Point (ZUP):
Dry contact input signal, connected to valid
o
The signal is turned on and the system controls the cutting head to lift.
•
Jogging Lower (ZDN):
Dry contact input signal, connected to valid
o
The signal is turned on and the system controls the cutting head to drop.
•
Upper Limit (UL):
Dry contact input signal, connected to valid
o
When the upper limit signal is input
ted
, the display "upper limit" indicator
light is
on and the cutting head stops moving upward and can be moved down
or reset
by manual operation to separate the cutting head from the upper limit.
•
Lower Limit (LL):
Dry contact input signal, connected to valid
o
When the lower limit signal is inputted, the display "lower limit" prompt is on
and the "hard limit alarm"is displayed. At the same time, the alarm output port
K1 and COM are connected. The user can customize the alarm output port K1
COM to connect with
a
CNC system.
FTC61 SERIES MANUAL
Document Number: 855-910
Revision: 001 Revision Date: 6/1/2019
BOSSLASER - PAGE 8 of 12