- 62 -
„stroke“
The stroke value determines in which stroke range the operating point
must lie and evaluates the riveting process with OK or NOK.
„current“
The current value determines the current range in which the operating
point must lie and evaluates the riveting process with OK or NOK.
„time“
The time defines the time range in which the operating point must lie
and evaluates the riveting process with OK or NOK.
„sampling rate“
For each step, an individual sampling rate can be selected for the graph
-
ic recording. This allows the recording to be optimised. If „Standard“
is selected, the step is recorded with the value set under „Settings“ →
„Graphics“ → „Sampling rate“ (chapter 4.4.11 on page 53).
„current rejection“
This function suppresses the starting current of the motor when using a
current setting in the strategy.
Recommended value: 0.25 seconds.