Cleaning and care 

The device does not need special attention for cleaning and care. The external surfaces can be cleaned with a damp 
cloth, if necessary with some detergents, then they have to be dry up. Do not use scratching, abrasive or corrosive 
products, as the surfaces could be damaged. Do not wash the water heater with direct or under pressure water jets. 

 

Water tank’s drain

  

To drain the water tank close the tap of cold water entry, and then open the appropriate tap knob for the drain (see 
pag.7 Pic. 4 - pos. E) and proceed until the tank is emptied. 

 

Precautionary measures to be followed in case of a long prolonged inactivity of the device or in case of 
frost  

After long inactivity period of the device, especially in cold places with under 0 temperature freezes, it is better to 
discharge the device.  

The discharge procedure must be carried out as explained above. The cold water feed and the gas feed must be closed 
carefully. 

 

Precautionary measures in case of device‘s troubles 

 

When there are working troubles, turn off the storage water heater, close all water and gas connections and call the 
clients assistance center or qualified technicians. 

-

 

The most common trouble is on the smokes sensor. If the device does not work because of this part, turn on 
the device again. In case of no resalt call a technician. 

-

 

The pilot burner lights up but the main burner does not: only in this case the injector may be obstructed. Call 
a technician to carry out a proper maintenance. 

Other faulty lightings may be provoked by a pressure oscillation in the feeder system or a gas lack in network. 

 

It is strictly forbidden to turn on the device without have followed these safety directions. 

Important note: always warn the assistance service.  

 

Summary of Contents for BGMAX 100

Page 1: ...Manual for installation and use FOR USER AND INSTALLER WALL HANG MULTIGAS STORAGE WATER HEATER Low Nox IT Cat II2H3P Prod ID Nr 0085CT0381 BGMAX 50 80 100...

Page 2: ...Pilot s injector replacement 13 Application removal of the mask for burner tube 13 Safety gas valve setting 14 Maintenance 15 Cleaning of the evacuation system of combustion gases 15 Smokes sensor re...

Page 3: ...ure inlet is summarized on the plate serial number placed on the frontal side of the devices on the left over the drive handle Dimensions Capacity Connections Model Weight kg Height mm Diam mm Litres...

Page 4: ...11BS B11BS Consumption LPG G31 Hi 12 87 kWh kg kg h 0 31 0 39 0 39 Natural Gas H G20 Hi 9 45 kWh m m h 0 44 0 53 0 53 Injectors in 1 100 mm LPG Pilot 25 1 25 1 25 1 Burner 095 110 110 Pressure injecto...

Page 5: ...The place for the installation must respect all the condition listed in the laws in force about gas plants for domestic use supplied by a distributing net Projecting installation and maintenance A co...

Page 6: ...s settle in the current laws Before connection you have to check if the gas available in the place corresponds to the type fixed in the device see plat serial number If the gas type is different you h...

Page 7: ...e of the product The connection for water exit is placed on the opposite side of cold water entry The water connection must be carried out with pipes a suitable for drinking water conduction Note use...

Page 8: ...xchanger and can be powered by alternative thermal sources through the connection to the domestic heating system or other alternative energy production system For this purpose thermo flow and thermo r...

Page 9: ...re tube must have a diameter according to the technical data schemes The laws in force on the matter must be followed The smokes sensor is a thermostat with a fixed setting If the draftdamper overheat...

Page 10: ...cold water discharge cock open the warm water exit cock We suggest to open a warm water tap of the domestic system so that air in pipe evacuates The necessary time for the filling is strictly connect...

Page 11: ...simulation must be carried out by inserting a pipe 50 cm long of a suitable diameter which must be plugged with a sheet metal The burner and the pilot must go out in two minutes from the moment in whi...

Page 12: ...device must be subjected to a functions examination and you have to update the supplementary plat according to the transformation which has been carried out Burner s injector replacement This operatio...

Page 13: ...s to LPG must be applied the mask for burner tube This operation must be carried out only by a qualified staff You have to follows these directions dismount the burner s cover and the burner s protect...

Page 14: ...A Set the screw which is visible after remove the protection To transform natural gas into LPG screw clockwise for seven or eight times to transform LPG into natural gas unscrew the screw anticlockwi...

Page 15: ...ount the screws on the new piece fix the screws To carry out the check of smokes sensor see the correspondent paragraph Safety gas valve replacement The replacement of a defected gas valve must be car...

Page 16: ...Boschetti Industrie Meccaniche srl 16 IT Ver 01 2019 Picture 13 Exploded drawing A 1 2 3 4 5 6 7 9 8 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Page 17: ...G 25 1 8 Ignition electrode 9 Safety gas valve SIT model 610 AC 3 10 Switch for thermocouple 11 Thermocouple 12 Double screw 13 Dual conic for tube 10 14 Nut for dual conic 15 Cover for gas valve 16 P...

Page 18: ...drinking and sanitary water any different use is not allowed Children must be kept away from gas devices Before turning on the device read carefully all the directions reported on this manual Do not l...

Page 19: ...returns to the position flame Note If the burner does not light up repeat the operation again a new attempt can carried out only after 2 3 minutes Temperature setting Set the thermostat as you please...

Page 20: ...h under 0 temperature freezes it is better to discharge the device The discharge procedure must be carried out as explained above The cold water feed and the gas feed must be closed carefully Precauti...

Page 21: ...fficiency class B Energy efficiency wh 54 Annual fuel consumption AFC 09 GJ Adjustment of the appliance thermostat E5 Interior noise level LWA 53 dB BGMAX 50 GPL Brand name Boschetti Industrie Meccani...

Page 22: ...iency wh 57 Annual fuel consumption AFC 08 GJ Adjustment of the appliance thermostat E5 Interior noise level LWA 53 dB BGMAX 100 GPL Brand name Boschetti Industrie Meccaniche srl Model BGMAX 100 GPL L...

Page 23: ...is not manipulated in any part and the label is not get away from the water heater 3 the problem is not due by exercise pression higher than the max pression written on the technical label 4 any parts...

Page 24: ...444 490636 Fax 39 0444 490496 E mail info boschettindustriemeccaniche it Internet www boschettindustriemeccaniche it The company is not liable for possible inaccuracies in these manual due to printing...