Commissioning
PSI 6XXX.190 W1
10-9
1070 080 086-101 (01.01) GB
10.7
Activating monitoring
For quality assurance,
Current Monitoring
should always be switched on, and the ap-
propriate tolerance bands should be entered.
The Actual Values are displayed and can be accepted as setpoints.
D
Activating monitoring
Select
Programming - Basic-Setup - Sequence Setup.
D
Enter
Current Monitoring
and the tolerance band
Select
Programming - Welding Parameters - Current Monitoring.
To facilitate the definition of the reference current and tolerance band, this window
shows an
Actual value
display.
10.8
Other adjustments and programs
When commissioning has been completed, you may protect access to the BOS-5000
software in order to restrict changing the
Welding Parameters
and the
Basic-Setup
by
defining user levels. A systems disk is needed for this purpose.
D
Use the
BOS-5000 Set-up
in the
System
menu for this purpose.
Other adjustments:
D
Maximum admissible limits for [%I] and [Pressure] correction by the user.
D
Regulation and monitoring mode
Other programs with slightly different parameters can be generated by copying.
D
Copying programs:
Select
Operation - Services - Copy.
Summary of Contents for WT PSI 6 Series
Page 1: ...PSI 6XXX 190 W1 Technical Information PSI 6000 101 Edition Description of Timer and I O Level ...
Page 3: ......
Page 7: ...Contents PSI 6XXX 190 W1 IV 1070 080 086 101 01 01 GB Your notes ...
Page 27: ...System PSI 6XXX 190 W1 1 6 1070 080 086 101 01 01 GB Your notes ...
Page 31: ...Technical data PSI 6XXX 190 W1 2 4 1070 080 086 101 01 01 GB Your notes ...
Page 41: ...Cables PSI 6XXX 190 W1 5 2 1070 080 086 101 01 01 GB Your notes ...
Page 43: ...Suppression of RF noise PSI 6XXX 190 W1 6 2 1070 080 086 101 01 01 GB Your notes ...
Page 71: ...Electrical connection PSI 6XXX 190 W1 7 28 1070 080 086 101 01 01 GB Your notes ...
Page 72: ...Control diagrams PSI 6XXX 190 W1 8 1 1070 080 086 101 01 01 GB 8 Control diagrams ...
Page 77: ...Control diagrams PSI 6XXX 190 W1 8 6 1070 080 086 101 01 01 GB ...
Page 107: ...PSI 6XXX 190 W1 Annex A 6 1070 080 086 101 01 01 GB Your notes ...
Page 108: ...1070 080 086 101 01 01 GB TB AT VWS Printed in Germany ...