![Bosch WT PSI 6 Series Technical Information Download Page 52](http://html.mh-extra.com/html/bosch/wt-psi-6-series/wt-psi-6-series_technical-information_50790052.webp)
Electrical connection
PSI 6XXX.190 W1
7-9
1070 080 086-101 (01.01) GB
7.2.2
External power supply
Configuration B
The power supply to PSI 6XXX.190 W1 is provided by an external unit (external supply).
Several jumpers have to be positioned to enable the external power supply.
The power supply to the timer is thus independent of the welding network.
For configuration B, the external power supply must satisfy the following requirements:
-
Maximum ripple <5 %, tolerance -15 % / +20 %.
-
Making current: approx. 2.0 A, duration approx. 10 ms, plus the current of
the inputs and outputs and the current of the external unit connected to X5.
-
continuous current: approx. 1.5 A, plus the current of the inputs and outputs
and the current of the external unit connected to X5.
NOTE
For determining the power supply rating, sum up the individual loads required.
Functions:
-
No interfaces are interrupted when the welding network is switched off:
-
communication via I/O interfaces is possible
-
communication between the timer and the programming terminal, e.g. pro-
gramming and visualization is possible.
-
Preferably used in networked systems
-
only one non-floating 24 V DC supply for the entire system
-
The
Stop function
is ensured by means of a
floating contact
which is to be con-
nected to terminals X4/3 and X4/4.
-
Opening the stop contact will interrupt:
-
the
firing
-
the
power supply
to the
parallel inputs and outputs
-
the
power supply
to the external unit.
Summary of Contents for WT PSI 6 Series
Page 1: ...PSI 6XXX 190 W1 Technical Information PSI 6000 101 Edition Description of Timer and I O Level ...
Page 3: ......
Page 7: ...Contents PSI 6XXX 190 W1 IV 1070 080 086 101 01 01 GB Your notes ...
Page 27: ...System PSI 6XXX 190 W1 1 6 1070 080 086 101 01 01 GB Your notes ...
Page 31: ...Technical data PSI 6XXX 190 W1 2 4 1070 080 086 101 01 01 GB Your notes ...
Page 41: ...Cables PSI 6XXX 190 W1 5 2 1070 080 086 101 01 01 GB Your notes ...
Page 43: ...Suppression of RF noise PSI 6XXX 190 W1 6 2 1070 080 086 101 01 01 GB Your notes ...
Page 71: ...Electrical connection PSI 6XXX 190 W1 7 28 1070 080 086 101 01 01 GB Your notes ...
Page 72: ...Control diagrams PSI 6XXX 190 W1 8 1 1070 080 086 101 01 01 GB 8 Control diagrams ...
Page 77: ...Control diagrams PSI 6XXX 190 W1 8 6 1070 080 086 101 01 01 GB ...
Page 107: ...PSI 6XXX 190 W1 Annex A 6 1070 080 086 101 01 01 GB Your notes ...
Page 108: ...1070 080 086 101 01 01 GB TB AT VWS Printed in Germany ...