Changing batteries
NOTE
Data buffering is assured for about 30 hours, without internal or external 24 VDC supply
voltage and after removing the battery.
A 3.6 V Lithium battery is installed in the PSI 6XXX.190 W1 to provide data backup power.
This battery supplies the RAM memory and the internal clock in the power down state.
Battery life is approx. 2 years.
If the battery voltage drops so far, that data buffering is no longer assured, the welding
timer will sense this state. The reaction to this event depends on the
Fault Allocation
in the
menu
Basic Setup.
-
If a low battery is defined as a fault, the control prevents the next start and the
Ready message turns off. The [Sequence] can resume after changing the battery
and resetting the fault.
-
If a low battery is defined as warning, the control will issue the appropriate mes-
sage, but [Sequence] will not be disabled.
To change the battery, first remove the cover to the battery compartment with CCW mo-
tion and remove the old battery. Then insert the new battery, while observing the correct
polarity (see illustration on front cover).
NOTE
To prevent loss of data, a bi-annual battery change is recommended as part of preventive
maintenance procedures.
CAUTION!
To prevent environmental harm, observe the currently valid disposal regulations for bat-
teries in effect.
CAUTION!
Danger of explosion: Never expose the battery to temperatures above 85
°
C. Do not at-
tempt to charge, solder or incinerate the battery. Do not short circuit or disassemble the
battery.
!
!
Summary of Contents for WT PSI 6 Series
Page 1: ...PSI 6XXX 190 W1 Technical Information PSI 6000 101 Edition Description of Timer and I O Level ...
Page 3: ......
Page 7: ...Contents PSI 6XXX 190 W1 IV 1070 080 086 101 01 01 GB Your notes ...
Page 27: ...System PSI 6XXX 190 W1 1 6 1070 080 086 101 01 01 GB Your notes ...
Page 31: ...Technical data PSI 6XXX 190 W1 2 4 1070 080 086 101 01 01 GB Your notes ...
Page 41: ...Cables PSI 6XXX 190 W1 5 2 1070 080 086 101 01 01 GB Your notes ...
Page 43: ...Suppression of RF noise PSI 6XXX 190 W1 6 2 1070 080 086 101 01 01 GB Your notes ...
Page 71: ...Electrical connection PSI 6XXX 190 W1 7 28 1070 080 086 101 01 01 GB Your notes ...
Page 72: ...Control diagrams PSI 6XXX 190 W1 8 1 1070 080 086 101 01 01 GB 8 Control diagrams ...
Page 77: ...Control diagrams PSI 6XXX 190 W1 8 6 1070 080 086 101 01 01 GB ...
Page 107: ...PSI 6XXX 190 W1 Annex A 6 1070 080 086 101 01 01 GB Your notes ...
Page 108: ...1070 080 086 101 01 01 GB TB AT VWS Printed in Germany ...