WFR 2460 Service Tips
WFR 2460 Service Tips
--
--
Resistance
Resistance
Measurements from Control Module (2)
Measurements from Control Module (2)
72
1st Edition/Revision 5 (1/20/04)
WARNING
! Unplug washer before
making any resistance measurements.
1
1
Disconnect & measure
white 5-pin
connector (with
3 black
wires) to
measure dual cold water valve. Valve
should read (pin 1 is at right):
•
Main wash (pins 1-3): 2.7 - 4.5 k
Ω
•
Prewash (pins 1-5):
2.7 - 4.5 k
Ω
1
1
Disconnect & measure
white 2-pin
connector (with
black
wires) to measure hot water valve. Valve
should read 2.7 - 4.5 k
Ω
.
Disconnect & measure 2 connectors to measure heater.
Measure between pin 1 (1-pin connector at bottom of group of 3
connectors at left of module) and pin 2 (2nd pin from right) of
pressure switch connector. Heater should read 23.2 - 29.4
Ω
..
Pink
connector
with
pink
wires
Connector
with
pink
wire
HINT
If necessary to access connectors,
carefully pry control module tabs and
remove module from fascia panel.
Summary of Contents for WFL 2060UC
Page 34: ...Disassembly Disassembly Drum Drive Motor Drum Drive Motor 34 1st Edition Revision 5 1 20 04 ...
Page 37: ...WFL 2060UC Circuit Diagram WFL 2060UC Circuit Diagram 37 1st Edition Revision 5 1 20 04 ...
Page 39: ...WFR 2460UC Circuit Diagram WFR 2460UC Circuit Diagram 39 1st Edition Revision 5 1 20 04 ...