WFR 2460 Service Tips
WFR 2460 Service Tips
--
--
Resistance
Resistance
Measurements from Control Module (1)
Measurements from Control Module (1)
71
1st Edition/Revision 5 (1/20/04)
1
1
1
1
1
1
Disconnect & measure
white 3-pin
connector (with
blue
wires) to
measure door latch motor. Measure
between pins 1-2 (pin 1 at far left).
Motor should read ~ 211 - 259
Ω
.
Disconnect & measure
white 2-pin
connector (with
black
wires) to
measure NTC. NTC should read:
•
20ºC (68ºF):
5.4 - 6.5 k
Ω
•
30ºC (86ºF):
3.5 - 4.3 k
Ω
•
40ºC (104ºF):
2.3 - 2.9 k
Ω
Disconnect & measure
blue
2-pin
connector (with
blue
wires) to
measure drain pump. Pump should
read ~ 80 - 94
Ω
.
Disconnect & measure
white 6-pin
connector (with
blue
wires) to
measure drum drive motor. Motor should read (pin 1 is at far right):
•
Pins 1-2:
14 - 35
Ω
•
Pins 3-4:
1.5 - 10
Ω
•
Pins 5-6:
0.7 - 2.1
Ω
WARNING
!
Unplug washer
before making
any resistance
measurements.