Alarm I/O Setup
Inputs Setup
Outputs Setup...
Physical
Input 1-7
2. Alarm Input 2
N.O.S.
Rule Setup...
3. Alarm Input 3
N.O.
Restore
Defaults...
4. Alarm Input 4
N.C.
5. Alarm Input 5
N.O.
6. Alarm Input 6
N.C.
7. Alarm Input 7
N.O.
8. NONE
9. NONE
Physical
Output
9-12
10. NONE
11. NONE
12. NONE
Focus / Iris: Select Type
Focus / Iris: Select
Right / Left: Select Mode
Alarm Setup Menu Choices:
Menu
Description
Sub-menu / Description
Default
Setting
Exit
Saves and exits the menu.
Inputs Setup
Defines physical inputs or events and
commands that can be used in a rule.
There are twelve (12) alarm inputs
available.
Inputs 1-7
Defines the type of physical input.
N.O.: Normally open dry contact.
N.C.: Normally closed dry contact.
N.C.S.: Normally closed supervised contact.
N.O.S.: Normally open supervised contact.
N.O.
Inputs 8-12
Defines input commands that can be
used in a rule. Command inputs can also
be customized by using non-assigned
keyboard command numbers.
NONE: No command defined.
Aux On: Responds to a standard or custom
keyboard ON (1-99) command.
Aux Off: Responds to a standard or custom
keyboard OFF (1-99) command.
Shot: Responds to a Preset shot or scene
from 1-99.
AutoTrack: Triggers an alarm when set to ON.
Motion Detection: Triggers an alarm when set
to ON.
NONE