![Bosch Solution 6+6 Wireless On/Off Quick Reference Manual Download Page 7](http://html.mh-extra.com/html/bosch/solution-6-6-wireless-on-off/solution-6-6-wireless-on-off_quick-reference-manual_39386007.webp)
Master Code Functions are designed to allow those users that have the appropriate access level to perform certain
functions of a supervisory level. These functions can only be carried out while the system is in a disarmed state.
+
+
Function
Description
0
Arming and Disarming Both Areas At The Same Time
1
Changing and Deleting User Codes/Radio Remote User Codes
2
Changing Phone Numbers (Domestic Only)
3
Event Memory Recall
4
Walk Test Mode
5
Fault Analysis
6
Setting The Date and Time
7
Toggle Day Alarm On and Off
8
Reset Latched Outputs
9
Initiate Modem Call
Master Code Functions
Fault Analysis
There are various system faults that can be detected by the
Solution 6+6 Wireless On/Off
control panel.
When any of these are present the
FAULT
indicator will begin to flash and the codepad will beep once every minute.
Hold the
5
button down for two seconds until two beeps are heard. The
STAY
and
AWAY
indicators will begin to
flash in unison with the
FAULT
indicator. One or more zone indicators (1-8) will illuminate to indicate the current
fault. Refer to the following table for a list of fault types.
Zone Indicator
Description
1
Low Battery
2
Date and Time
3
Sensor Watch
4
Horn Speaker Disconnected
5
Reserved
6
E
2
Fault
7
Reserved
8
Communications Failure
Fault Types
User Code Functions
+
+
Function
Description
0
Arming and Disarming Both Areas At The Same Time
Solution 6+6 Wireless On/Off
Quick Reference Guide
ISSUE 1.20
Electronics Design & Manufacturing Pty Limited
Page 7