Introduction
Thankyou for choosing the
Solution 6+6 Wireless On/Off
control panel for your installation. We are sure
that you will find this system extremely flexible, reliable and easy to use.
Before using the system for the first time, we suggest that you read the section in this Quick Reference Guide called
“Programming Using a Codepad” to familiarise yourself with the basic programming methodology.
The Quick Reference Guide is supplied with the control panel to provide users with enough basic information to wire,
configure and operate the system. Due to the systems many programmable features and options, we suggest that you
obtain the complete Installation Manual which provides detailed information on all system options and functions as
well as detailed information on the numerous programming methods.
Programming
The programming options of this system are stored in a non volatile EPROM. This memory will hold all the relevant
configuration and user specific data even during a total power loss.
The data retention time is as long as ten years without power, therefore no reprogramming will be required after
powering the system down.
The data can be altered as many times as required without the need for any additional specialised equipment. This
memory is laid out in numerous locations each of which holds the data for a specific function. In general, the entire
programming sequence will consist of nominating the location number and then entering or altering the required data.
You will repeat this procedure until all the data has been altered to suit your requirements. The factory default settings
have been selected for the control panel to report in Contact ID format.
Note:
'15' is the maximum value that can be programmed into any location.
There are two programming modes. The Installer’s Programming Mode and the Operators Programming Mode. Both
modes have individual access codes and these two codes must always be programmed differently. The Master Code, as
well as being able to arm and disarm the system gives access to the Operators Programming Mode. The Installer’s
Code only gives access to the Installer’s Programming Mode and does NOT arm and disarm the system.
Programming of the
Solution 6+6 Wireless On/Off
control panel can be carried out via any of the
following four methods.
System
Codepad
Hand Held Programmer
(CC814)
Programming Key (CC810)
Alarm Link (Upload/Download) Software (CC816)
Note: For further information on the different programming options available for the
Solution 6+6
Wireless On/Off
control panel, refer to the Installation Manual (MA670I).