Location
428 429 430 431 432 433
434 435
Zone 12
0
0
0
0
1
3
0
1
(Default = Instant)
Zone
Type
Zone
Options
Zone
Pulse
Count
Zone
Pulse
Count Time
Event
Code
Hundreds
Digit
Event
code
Tens
Digit
Event
Code
Units
Digit
Dialler
Channel
Location
436 437 438 439 440 441
442 443
Zone 13
0
0
0
0
1
3
0
1
(Default = Instant)
Zone
Type
Zone
Options
Zone
Pulse
Count
Zone
Pulse
Count Time
Event
Code
Hundreds
Digit
Event
code
Tens
Digit
Event
Code
Units
Digit
Dialler
Channel
Location
444 445 446 447 448 449
450 451
Zone 14
0
0
0
0
1
3
0
1
(Default = Instant)
Zone
Type
Zone
Options
Zone
Pulse
Count
Zone
Pulse
Count Time
Event
Code
Hundreds
Digit
Event
code
Tens
Digit
Event
Code
Units
Digit
Dialler
Channel
Location
452 453 454 455 456 457
458 459
Zone 15
0
0
0
0
1
3
0
1
(Default = Instant)
Zone
Type
Zone
Options
Zone
Pulse
Count
Zone
Pulse
Count Time
Event
Code
Hundreds
Digit
Event
code
Tens
Digit
Event
Code
Units
Digit
Dialler
Channel
Location
460 461 462 463 464 465
466 467
Zone 16
0
0
0
0
1
3
0
1
(Default = Instant)
Zone
Type
Zone
Options
Zone
Pulse
Count
Zone
Pulse
Count Time
Event
Code
Hundreds
Digit
Event
code
Tens
Digit
Event
Code
Units
Digit
Dialler
Channel
Zone Types
Zone
Type Description Zone
Type Description
0
Instant
8
Delay-1 (Auto Isolated In STAY Mode 1)
1
Handover
9
Delay 2 (Auto Isolated In STAY Mode 1)
2
Delay-1
10
Delay-3 (Auto Isolated In STAY Mode 1)
3
Delay-2
11
Delay-4 (Auto Isolated In STAY Mode 1)
4
Delay-3
12
24 Hour Burglary
5
Delay-4
13
24 Hour Fire
6
Instant (Auto Isolated In STAY Mode 1)
14
Chime
7
Handover (Auto Isolated In STAY Mode 1)
15
Not Used
Zone Options
Dialler Channel
Option Description
Option Group
1
Lockout Siren
1
Group 1 (Area 1)
2
Lockout Dialler
2
Group 2 (Area 2)
4
Silent Alarm
3
Group 3 (Area 3)
8
Sensor Watch
4
Group 4 (Area 4)
Zone Pulse Count
The pulse count allows you to program how many pulses (0 – 15) need to be registered within the pulse count
time to activate an alarm.
Zone Pulse Count Time
Option
20ms Loop Response Time
Option
150 ms Loop Response Time
0
0.5 Seconds
8
20 Seconds
1
1 Second
9
30 Seconds
2
2 Seconds
10
40 Seconds
3
3 Seconds
11
50 Seconds
4
4 Seconds
12
60 Seconds
5
5 Seconds
13
90 Seconds
6
10 Seconds
14
120 Seconds
7
15 Seconds
15
200 Seconds
Event Code
The three-digit event code is used to describe the zone function when reporting in Contact ID format (Eg.
Entry/Exit, Tamper, Perimeter etc). Refer to the installation manual for a full list of Contact ID codes available.
When the system is reporting in a format other then Contact ID, the event code are programmed as follows:
Hundreds Digit
= Alarm Restore Report (0 = Alarm Restore Disabled)
Tens Digit
= Alarm Report (0 = Alarm Disabled)
Units Digit
= Channel Code (0 = Disabled)
Solution-16/Solution-16
Safecom
Quick Reference Guide
11
Bosch Security Systems Pty Limited