background image

 

Location 624 - 625 

Entry Time 1 

Location 626 - 627 

Entry Time 2 

Location 628 - 629 

Entry Time 3

 

Location 630 - 631 

Entry Time 4

 

 

Location 632 - 633 

Exit Time For AWAY Mode  

Location 634 - 635 

Exit Time For STAY Mode 1 

Location 636 - 637 

Exit Time For STAY Mode 2

 

Location 638 - 639 

Entry Guard Time 
For STAY Mode 1 and 2 

Location 640 - 641 

Codepad Lockout Time

 

 

Location 642 - 643 

Sensor Watch Time

 

 

Location 644 - 649 

System Date 

(V1.10) 

 
 
 
 
Location 644 - 649 

System Date 

(V1.20+) 

 
 
 
 
Location 650 - 653 

Auto Arming Time

 

 
 
 
Location 654 

Auto Arming Pre-Alert Time 

Location 655 

Timed Output 
Pre-Alert Time 

Location 656 - 659 

Auto Operation Of The 
Timed Output

 

 
 
 

10 0

Location 624 = Increments Of 1 Second (0 – 15 Seconds) 
Location 625 = Increments Of 16 Seconds (0 – 240 Seconds) 

Location 626 = Increments Of 1 Second (0 – 15 Seconds) 
Location 627 = Increments Of 16 Seconds (0 – 240 Seconds) 

4 1

14 1

Location 628 = Increments Of 1 Second (0 – 15 Seconds) 
Location 629 = Increments Of 16 Seconds ( 0 – 240 Seconds) 

Location 630 = Increments Of 1 Second (0 – 15 Seconds) 
Location 631 = Increments Of 16 Seconds (0 – 240 Seconds) 

8 2

12 3

Location 632 = Increments Of 1 Second (0 – 15 Seconds) 
Location 633 = Increments Of 16 Seconds (0 – 240 Seconds) 

Location 634 = Increments Of 1 Second (0 – 15 Seconds) 
Location 635 = Increments Of 16 Seconds (0 – 240 Seconds) 

12 3

12 3

Location 636 = Increments Of 1 Second (0 – 15 Seconds) 
Location 637 = Increments Of 16 Seconds ( 0 – 240 Seconds) 

Location 638 = Increments Of 1 Second (0 – 15 Seconds) 
Location 639 = Increments Of 16 Seconds (0 – 240 Seconds) 

12 3

Location 640 = Increments Of 1 Second (0 – 15 Seconds) 
Location 641 = Increments Of 16 Seconds (0 – 240 Seconds) 

0 0

Location 642 = Increments Of Days (Tens Digit) 
Location 643 = Increments Of Days (Units Digit) 

0 0

Location 644 = Day Of The Week (Sun = 1 Sat = 2) 
Location 645 = Month Of The Year (Jan = 1 Dec = 12) 
Location 646 = Day Of The Month (Tens Digit) 
Location 647 = Day Of The Month (Units Digit) 
Location 648 = Current Year (Tens Digit) 
Location 649 = Current Year (Units Digit) 

644 645    646 647

  648 649

1 1  0 1

 9 5

D M  D D  Y Y 

Location 644 = Day Of The Month (Tens Digit) 
Location 645 = Day Of The Month (Units Digit) 
Location 646 = Month Of The Year (Tens Digit) 
Location 647 = Month Of The Year (Units Digit) 
Location 648 = Current Year (Tens Digit) 
Location 649 = Current Year (Units Digit) 

644 645    646 647

  648 649

0 1  0 1

 9 5

D D  M M  Y Y 

Location 650 = Hour Of The Day (Tens Digit) 
Location 651 = Hour Of The Day (Units Digit) 
Location 652 = Minute Of The Day (Tens Digit) 
Location 653 = Minute Of The Day (Units Digit) 

650 651

  652 653

0 0

:

0 0

H H    M M 

5

0 = No Pre-Alert Time / 1 - 15 = Pre-Alert Time In Minutes (Default = 5 Min’s) 

5

0 = No Pre-Alert Time / 1 - 15 = Pre-Alert Time In Minutes (Default = 5 Min’s) 

Location 656 = Hour Of The Day (Tens Digit) 
Location 657 = Hour Of The Day (Units Digit) 
Location 658 = Minute Of The Day (Tens Digit) 
Location 659 = Minute Of The Day (Units Digit) 

656 657

  658 659

0 0

:

0 0

H H    M M 

Solution-16/Solution-16 

Safecom

 Quick Reference Guide

 

15 

 

Bosch Security Systems Pty Limited 

 

Summary of Contents for Solution-16 safecom

Page 1: ...Solution 16 Solution 16 Safecom Quick Reference Guide ISSUE 2 41 ...

Page 2: ...ing recording or otherwise without the prior written permission of Bosch Security Systems Pty Limited Trademarks Throughout this document trademark names may have been used Rather than put a trademark symbol in every occurrence of a trademark name we state that we are using the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringement of the tra...

Page 3: ...t data programmed in LOCATION 000 First location of the Primary Telephone Number To move to another programming location enter the location number followed by the key The data in the new location will now be displayed via the codepad indicators Eg If you entered 52 the system will jump you to LOCATION 052 the beginning of the Subscriber ID Number For Area 1 To move to the next location press the k...

Page 4: ...ion Description 1 Dialler Reporting Functions Allowed 2 Remote Arming Via Telephone Allowed 4 Upload Download Via Alarm Link Allowed 8 Terminate Alarm Link Session On Alarm Installer s Programming Commands These commands can only be used when you enter Installer s Programming Mode Enter the command followed by the key Command Description 958 Enable Disable Zone Status Hand Held Programmer Required...

Page 5: ...followed by the key eg 2580 STAY Mode 2 1 Press and hold the 0 key until two beeps are heard Only if no alarm Or 2 Enter your code followed by the key eg 2580 Disarm All Areas Partitioning 1 Enter your code followed by 0 and then the key eg 2580 0 This function allows a code to disarm all areas that the code is assigned to at the same time without the need to disarm each area individually Isolatin...

Page 6: ... and the key eg 2580 1 2 Enter the User Number that you want to add change followed by the key 3 Enter the New Code followed by the key Delete A User Code V1 10 1 Enter the Master Code followed by 1 and the key eg 2580 1 2 Enter the User Number that you want to delete followed by the key 3 Press the key again to delete the user code Delete A User Code V1 20 1 Enter the Master Code followed by 1 an...

Page 7: ...Link 1 Press and hold the 6 key until two beeps are heard Latching Outputs Reset 1 Press and hold the 7 key until two beeps are heard Codepad ID Buzzer Tone 1 Press and hold the 8 key until the desired buzzer tone has been reached If the system has been partitioned the codepad will display a number to identify which area the codepad belongs to see table below 2 Press the key to terminate Zone LED ...

Page 8: ...r Code 11 Authority Level User Code 12 Authority Level Location 136 142 143 Location 144 150 151 Location 152 158 159 15 15 15 15 15 15 15 0 15 15 15 15 15 15 15 0 15 15 15 15 15 15 15 0 User Code 13 Authority Level User Code 14 Authority Level User Code 15 Authority Level Location 160 166 167 Location 168 174 175 Location 176 182 183 0 0 0 0 0 0 0 0 15 15 15 15 15 15 15 0 15 15 15 15 15 15 15 0 0...

Page 9: ... 15 15 15 15 0 15 15 15 15 15 15 15 0 15 15 15 15 15 15 15 0 User Code 31 Authority Level User Code 32 Authority Level Location 304 310 311 Location 312 318 319 15 15 15 15 15 15 15 0 0 15 15 15 15 15 15 1 Authority Levels Authority Level Description 0 Arm Disarm 1 Arm Only 2 Patrolman Code 4 Arm Disarm Code Required To Isolate 6 Patrolman Code Code Required To Isolate 8 Master Code Arm Disarm 12 ...

Page 10: ...nt Time Event Code Hundreds Digit Event code Tens Digit Event Code Units Digit Dialler Channel Location 388 389 390 391 392 393 394 395 Zone 7 0 0 0 0 1 3 0 1 Default Instant Zone Type Zone Options Zone Pulse Count Zone Pulse Count Time Event Code Hundreds Digit Event code Tens Digit Event Code Units Digit Dialler Channel Location 396 397 398 399 400 401 402 403 Zone 8 12 0 0 0 1 3 3 1 Default 24 ...

Page 11: ...to Isolated In STAY Mode 1 2 Delay 1 10 Delay 3 Auto Isolated In STAY Mode 1 3 Delay 2 11 Delay 4 Auto Isolated In STAY Mode 1 4 Delay 3 12 24 Hour Burglary 5 Delay 4 13 24 Hour Fire 6 Instant Auto Isolated In STAY Mode 1 14 Chime 7 Handover Auto Isolated In STAY Mode 1 15 Not Used Zone Options Dialler Channel Option Description Option Group 1 Lockout Siren 1 Group 1 Area 1 2 Lockout Dialler 2 Gro...

Page 12: ...ble Report Location 473 Trouble Restore Report Location 474 Trouble Report Location 475 Trouble Restore Report 9 9 1 2 1 1 Location 476 478 Contact ID Event Code Hundreds Tens Units Location 479 Dialler Channel 1 2 0 1 Location 480 482 Contact ID Event Code Hundreds Tens Units Location 483 Dialler Channel 4 2 1 1 Location 484 486 Contact ID Event Code Hundreds Tens Units Location 487 Dialler Chann...

Page 13: ... Event Code Polarity Time Base Time Base Multiplier Default Area 3 In Alarm Strobe Event Code Polarity Time Base Time Base Multiplier Location 612 613 614 615 616 617 Location 618 619 620 621 622 623 Output 13 5 5 6 3 1 0 Output 14 5 5 6 3 6 0 Default Area 4 In Alarm Siren Event Code Polarity Time Base Time Base Multiplier Default Area 4 In Alarm Strobe Event Code Polarity Time Base Time Base Mult...

Page 14: ...4 6 Zone Not Sealed 6 3 Area 4 Codepad Data Terminal 4 7 Reserved Polarity Modes Option Description Option Description 0 Disabled 7 Reserved 1 Normally Open Going Low 8 Normally Low Going Open 2 Normally Open Pulsing Low 9 Normally Low Pulsing Open 3 Normally Open One Shot Low 10 Normally Low One Shot Open 4 Normally Open One Shot Low Reset 11 Normally Low One Shot Open Reset 5 Normally Open One S...

Page 15: ... Seconds 0 240 Seconds Location 638 Increments Of 1 Second 0 15 Seconds Location 639 Increments Of 16 Seconds 0 240 Seconds 12 3 Location 640 Increments Of 1 Second 0 15 Seconds Location 641 Increments Of 16 Seconds 0 240 Seconds 0 0 Location 642 Increments Of Days Tens Digit Location 643 Increments Of Days Units Digit 0 0 Location 644 Day Of The Week Sun 1 Sat 2 Location 645 Month Of The Year Jan...

Page 16: ... 1 1 Forced Arming Allowed 2 Smart Lockout Allowed 4 Horn Speaker Monitor 8 Horn Speaker Beeps Allowed 2 1 Keyswitch Interface Night Arm Station or RE005 Installed 2 Handover Delay To Be Sequential 4 Codepad Panic To Be Silent 8 Access Denied Code Retries Codepad Tamper To Be Silent 0 1 Area 1 Codepad Connected To Main Data Terminal 2 Modem Module Required For Alarm Link Operation 4 AC Fail After ...

Page 17: ...Y Mode 1 12 Latching Arm Disarm Area 4 0 0 1 Display FAULT Indicator If Telephone Line Fails 2 Sound Alarm When System Is Armed If Telephone Line Fails 4 Sound Alarm When System Is Disarmed If Telephone Line Fails Note Option 2 4 Must Be Used In Conjunction With Option 1 Eg Program a 1 3 5 or 7 Location 674 Open Report Location 675 Close Report 0 0 Location 676 Open Report Location 677 Close Repor...

Page 18: ...one 5 LED Area 3 Codepad Location 713 Zone 6 LED Area 3 Codepad Location 714 Zone 7 LED Area 3 Codepad Location 715 Zone 8 LED Area 3 Codepad 708 709 710 711 712 713 714 715 0 0 0 0 0 0 0 0 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Location 716 Zone 1 LED Area 4 Codepad Location 717 Zone 2 LED Area 4 Codepad Location 718 Zone 3 LED Area 4 Codepad Location 719 Zone 4 LED Area 4 Codepad Location 720 Zone 5 LED Area 4...

Page 19: ...846 Increments Of 5 ms 0 ms 75 ms Location 847 Increments Of 80 ms 0 ms 1200 ms 0 0 Location 846 Increments Of 5 ms 0 ms 75 ms Location 847 Increments Of 80 ms 0 ms 1200 ms 4 6 6 1 Safecom Communication Reporting Disabled 2 Arming From ST1000 Base Allowed 4 Disarming From ST100 Base Allowed 8 Reserved 0 1 Send Test Report At End Of Siren Time 2 Power Up In Disarmed State Re Boot 4 Internal Crystal...

Page 20: ...6 Zone Operation Connections For Split EOL Resistors For 16 Zone Operation Using N O Contacts Safecom Interface 20 Solution 16 Solution 16 Safecom Quick Reference Guide SOL 16 SAFECOM QUICK REF GUIDE DOC DOC Bosch Security Systems Pty Limited ...

Page 21: ...Component Overlay Solution 16 Solution 16 Safecom Quick Reference Guide 21 Bosch Security Systems Pty Limited ...

Page 22: ...Wiring Diagram 22 Solution 16 Solution 16 Safecom Quick Reference Guide SOL 16 SAFECOM QUICK REF GUIDE DOC DOC Bosch Security Systems Pty Limited ...

Page 23: ...d Connections Partitioning Note A Master Partitioned codepad requires all DIP Switches to be set in the ON position Solution 16 Solution 16 Safecom Quick Reference Guide 23 Bosch Security Systems Pty Limited ...

Page 24: ......

Reviews: