1 689 989 261
2019-04-08
|
Robert Bosch GmbH
34 | SMT 300 | Maintenance
8. Maintenance
!
Work on electrical equipment is only to be per-
formed by persons with sufficient knowledge and
experience of electrical systems!
8.1
Cleaning
!
Do not use abrasive cleaning agents and coarse
workshop cloths!
¶
The housing and the LCD are only to be cleaned
using a soft cloth and neutral cleaning agents.
en
8.2
Maintenance
!
Empty the SMT 300 before sending for servicing, as
otherwise the oil can drain out.
8.3
Changing the battery in the
multi-function lamp
xxx
1
3
2
4
Fig. 10: Multi-function lamp (components)
1 Multi-function key
2 Housing
3 Battery holder with microbatteries (3 x AAA)
4 Cover
1.
Unscrew the cover from the housing
2.
Remove the battery holder with microbatteries from
the housing.
3.
Remove old batteries from the battery holder.
4.
Insert new microbatteries (3 x AAA) in the direction
shown on the insides of the openings in the battery
holder.
5.
Insert the battery holder into the housing in accor-
dance with the direction shown by the arrow on the
holder.
6.
Screw the rear cover onto the housing.
i
For disposal of the old batteries from the multi-func-
tion lamp, see sec. 9.3.
8.4
Spare and wearing parts
Designation
Order number
Smoke supply hose (2,5 m) with Delrin® nozzle
<)
1 680 703 080
UltraTraceUV
®
smoke solution
<)
F 00E 900 348
Connector cap kit
1 680 322 069
Adapter cone
1 681 334 039
Smoke diffuser
1 681 390 002
Multi-function lamp (incl. UV safety goggles
and 3 microbatteries)
1 687 550 077
UV safety goggles
1 682 777 092
EVAP service port connector, standard size
<)
1 683 457 130
Schrader removal/installation tool
<)
1 687 012 181
Fuel filler neck:
– Universal adapter
– BMW Mini adapter
1 681 335 125
1 681 335 126
<)
Wearing part