Security Escort
Installation instructions | en
21
Robert Bosch (SEA) Pte Ltd
Hardware Installation Manual
2018.03 | SE3v1.0 | DOC
4
Installation instructions
4.1
Overview of installation process after survey
This section includes information about the installation and setup of the individual
components and system wiring. It is recommended that the installation instructions that
accompany each specific component be consulted prior to beginning any phase of the
installation.
A typical installation proceeds in the following order:
1.
The site survey is completed, indicating the proposed location of each component.
2.
Wiring runs to all of the proposed component locations and the Central Console.
3.
Empty enclosures are installed as specified in the site survey.
4.
The components are secured inside the enclosures and connected to the previously run
wiring. The individual components are set up and their addresses recorded.
Notice!
Use the
SE Coordinator Information Sheet
, located in the
Appendix
of this document, to keep
track of SE receiver addresses and location for programming the
Transponder Database
.
5.
The recorded addresses are entered into the Central Console and the system is brought
on-line.
6.
The system is tested and tuned up as needed.
4.2
Run system wiring
4.2.1
General guidelines
After the site survey (and special pre-installation verifications) has been completed, the wiring
can be run between the proposed locations of the system components and the Central
Console. See specific installation instructions accompanying each component for wiring
details.
The following table indicates the specifications for the wiring:
From
To
Signal Type Gauge
Max. Length Remark
SE
coordinator /
SE receiver
SE receiver
RS-485
#24
1000 m per
bus
Twisted pair Cat5e
cable recommended.
Shielded cable may
be required for
outdoor use.
Power
Supply
Power
#18
Please refer to the sections below
for detailed specification.
#24
Input 1 or 2
I/O
#18
15 m
Solid, not twisted, not
shielded
Output 1 or 2 I/O
#18
15 m
Solid, not twisted, not
shielded
SE coordinator Host PC
Ethernet /
PoE
Cat5e
UTP
100 m
Shielded cable may
be required for
outdoor use
Tab.
4.1:
Specifications for Wiring