This connection is used for device variants for 230/115 VAC.
All internally required voltages are generated by the 230/115 VAC power
supply unit.
CAUTION
The supply voltage must comply with
overvoltage category II! Otherwise the
integrated power supply unit might be
destructed.
⇒
Use an isolating transformer to generate the
230/115 VAC (see following page).
The 230/115 VAC connection occurs via a 3-pin inlet connector for AC
connectors on the connector panel. The maximum cable cross section for
the connected cables is 1.5 mm
2
.
X20
Assignment
PE
N1
U2
PE
230V_Buchse.cdr
Fig. 7-15:
Pin assignment of the 230/115 VAC connection X20
Parameters
Value
Rated voltage
85 VAC ... 264 VAC auto range
Power consumption for U
N
= 230 VAC
2.5 A
Power consumption for U
N
= 115 VAC
5 A
Inrush current for 264 VAC
100 A
Overload protection
As of 135 %, deactivation
Short-circuit protection
At all outputs, deactivation
Fig. 7-16:
Technical data 115/230 VAC connection
230/115 VAC Power Supply
Summary of Contents for Rexroth VSB 40.1
Page 7: ...IV Contents VSB 40 1 DOK SUPPL VSB 40 1 PR02 EN P ...
Page 27: ...4 6 Technical Data VSB 40 1 DOK SUPPL VSB 40 1 PR02 EN P ...
Page 79: ...12 4 List of Figures VSB 40 1 DOK SUPPL VSB 40 1 PR02 EN P ...
Page 83: ...13 4 Index VSB 40 1 DOK SUPPL VSB 40 1 PR02 EN P ...
Page 85: ...14 2 Service and Support VSB 40 1 DOK SUPPL VSB 40 1 PR02 EN P ...
Page 86: ......