Error/warning,
diagnostic
code: Text
Cause
Remedy
E2015, B505A: pressure
chamber B exceeds upper
warning level
Process pressure monitoring of
chamber B signals a warning.
Take hydraulic remedial action
Check machine cycle; the machine might be operated
outside its specification
Where appropriate, raise alarm threshold via
P‑0‑1389[416]
or
extend
debounce
time
P‑0‑1389[415]
E2015, B505B: config data
not feasible P1389.402
The upper limit of the value range
for scaling an analog input is incor‐
rectly configured.
A value greater than "0” has to be entered in
P‑0‑1389[402].
Tab. 14-2:
Errors/warnings
For further diagnostic messages, see commissioning instructions
"Rexroth Sytronix SvP 7020 PFC, R911379550", chapter 8.3.2
“Diagnostic messages”.