18/20
Bosch Rexroth AG
Assembly Instructions for Hydraulic Power Units | RE 07009-MON/11.17
6.5.2 Laying the power supply and control cables and connecting
the electricity supply
f
The electrical installation must be performed in accordance with the currently
applicable rules of electrical engineering.
f
You must ensure that the power supply is disconnected and also safeguarded
against being switched on unintentionally.
f
You should prevent this by e.g. using a warning sign to draw attention to
issues regarding working on the electrics.
f
Carefully secure all cables to the electric motor with plastic cable clamps
against unintended loosening (swinging).
6.5.3 Installing the electrical control and monitoring equipment
Connect the control and monitoring equipment (switching devices, open-loop
or closed-loop equipment or frequency converters) according to the relevant
instructions, taking into account the appropriate safety precautions.
Penetrating dirt and liquids will cause faults!
Safe function of the hydraulic power unit/components is then no longer ensured.
f
Always ensure absolute cleanliness when working on the hydraulic power unit.
Damage to the surface from solvents and aggressive cleaning agents!
Aggressive detergents may damage the seals on the hydraulic power unit and
make them age faster.
f
Never use solvents or aggressive detergents.