14/20
Bosch Rexroth AG
Assembly Instructions for Hydraulic Power Units | RE 07009-MON/11.17
5.2 Storing the hydraulic power units
Observe the storage times specified in Table 2.
f
If the storage time exceeds the values specified, flush the hydraulic power unit
before commissioning using a suitable flushing fluid. The flushing procedure
should be carried out as described in Chapter 7.1.9 “Flushing the hydraulic
system” of the operating instructions.
f
If necessary, replace the components for which a maximum storage time is
specified e.g. hoses, compensators, accumulators.
Table 2: Storage times
6 Assembly and installation
This chapter describes the assembly of the product at its place of use as well as
the connection of the product to the hydraulic system, the electrical systems and
the water supply of the machine.
For information regarding the installation into the complete machine, particularly
regarding its overall function and logic mode of operation, please refer to the
instructions and/or the documentation for the complete machine.
Risk of personal injury and damage to property!
A basic knowledge of hydraulics is required for assembling the hydraulic power
unit.
f
Only qualified personnel (see Chapter “2.3 Personnel qualifications”) are
permitted to assemble the hydraulic power unit.
6.1 Unpacking
f
Remove the product packaging.
f
Dispose of the packaging material in accordance with the national regulations
in your country and/or your company-internal specifications/procedures.
CAUTION!
Storage conditions
Packaging
Protective
agent
Storage time in months
Test with the protective agent
Filling with the protective agent
Storage in dry rooms
at
constant temperature
For carriage
overseas
A
12
24
B
12
24
Not for carriage
overseas
A
9
24
B
12
24
Outdoor storage
(protect the product against
damage and water ingress)
For carriage
overseas
A
6
12
B
9
24
Not for carriage
overseas
A
0
12
B
6
24
Inspection with protective agent A = Mineral oil
Filling with protective agent B = Corrosion protection oil