In operation
Storage / Transport
Air pressure
Up to 2 000 m above MSL according to DIN 60204
Mechanical strength
Max. vibration:
Frequency range: 10-150 Hz
Excursion: 0.075 mm for 10-57 Hz
Acceleration: 1 g for 57-150 Hz
According to EN 60068-2-6
Max. shock: 15 g according to DIN
IEC 68-2-27, function not disturbed
Fig.4-2:
Ambient conditions
4.4
Standards
4.4.1
Used Standards
The system components of the displays correspond to the following standards:
Standard
Meaning
EN 60 204-1
Electrical equipment of machines
EN 50 081-2
Basic technical standard, noise immunity (industrial en‐
vironment)
EN 50 082-2
Basic technical standard, emitted interference (industrial
environment)
EN 60 742
Transformer for 24 V power supply unit, protective sepa‐
ration
EN 60 950
Overvoltage category II
EN 61 131
Requirements regarding the 24V outputs
EN 61 131-2
Requirements on the 24 power supply
EN 418
Machine safety, EMERGENCY STOP devices
EN 60 529
Degrees of protection (incl. housings and installation
compartments)
EN 60 068-2-6
Vibration test
EN 60068-2-27
Shock test
Fig.4-3:
Used standards
4.4.2
CE Marking
Declaration of Conformity
The electronic products described in the project planning manual comply with
the requirements and goals of the following EC guideline and with the agreed
European standards:
EMC guideline 2004/108/EC
The electronic products described in the project planning manual comply with
the requirements on the operation within the industrial environment:
16/52
Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraControl VDP 92.3 | Project Planning Manual
Technical Data
EN Standards