Bridging time
Maximum 3 minutes
Maximum output power in the buffer mode 60 W
Fig.4-4:
Output voltage
4.3
Ambient Conditions
In operation
Storage / Transport
Surrounding air
temperature
+5 to +45 °C
-20 °C to +60 °C
Maximum tem‐
perature gradi‐
ent
Temperature change up to 3°C
per minute
Temperature change up to 3°C
per minute
Relative humid‐
ity
Climatic class 3K3 according to
EN 60721, condensation not per‐
missible.
80 % humidity max. for 25 °C
Climatic class 3K3 according to
EN 60721, condensation not per‐
missible.
80 % humidity max. for 25 °C
Air pressure
Up to 2,000 m above MSL ac‐
cording to DIN 60204
Up to 3000 m above MSL accord‐
ing to DIN 60204
Mechanical
strength
Maximum vibration
Frequency range: 10 to 150 Hz
Excursion: 0.075 mm for 10 to 57
Hz
Acceleration: 1 g for 57 to 150 Hz
Test duration for each axis: 10
frequency cycles
Frequency sweep rate:
1 octave/min
According to EN 60068-2-6, test
Fc
Maximum shock:
15 g according to EN 60
068-2-27, no disturbance of the
function
Degree of pollu‐
tion
2
2
Fig.4-5:
Ambient Conditions
4.4
Standards
4.4.1
Used Standards
The system components of the VAU 01.1Z correspond to the following stand‐
ards:
Standard
Meaning
EN 60 61000-6-4
Generic standard, emitted interference (industrial environ‐
ment)
EN 60 61000-6-2
Generic standard, noise immunity (industrial environment)
EN 60664-1
Overvoltage category II
EN 60950
Clearances and creepage distances office (environment)
and power units
16/45
Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraControl VAU 01.1Z | Project Planning Manual
Technical Data