SEL
MOD
Operator display 1 (XCDI+tx1)
Operator display 2 (XCDI+tx1)
0
1
Active
Active
1
1
-
-
0
Open or 0 V
1
24 V
Tab. 12-1: The operation modes are selected using the inputs "SEL" and "MOD"
12.2 Display elements
There are five LEDs on the CDI+ splitter (see
fig. 9-1 "Connector panel of the
). The LEDs indicate the current operating state.
LED
Description
Vin
Display of the 24 V voltage supply
Video1
Link1
Operating state, operator display 1
Video2
Link2
Operating state, operator display 2
Tab. 12-2: LEDs at the CDI+ splitter
12.3 Operating and error display
Start the measures specified in the following table if one of the LEDs is on.
LED
Name
Description
Action
V
IN
LED is on
Normal mode
-
LED is off
24 V DC missing
Check the cable of the voltage supply
which is connected to X1S1.
Video1
LED flashing
green
Image data is sent to the operator
display 1.
-
LED off
The PC does not sent any image data
to the CDI+ splitter
-
Link1
LED green
Communication active und operator
panel selected.
-
LED red
Operator panel not selected and no
communication possible with the op-
erator panel
-
LED green
and red
Operator panel not selected, but the
communication is possible with the
operator panel
-
LED off
No communication possible with the
operator display, even though it is ac-
tive (selected via SEL or MOD)
-
IndraControl VAC 08.1 CDI+ Splitter
25/33
Device description
R911400465_Edition 01 Bosch Rexroth AG
Summary of Contents for rexroth IndraControl VAC 08.1
Page 1: ...IndraControl VAC 08 1 CDI Splitter Operating Instructions R911400465 Edition 01 ...
Page 6: ...IV IndraControl VAC 08 1 CDI Splitter Bosch Rexroth AG R911400465_Edition 01 ...
Page 36: ...30 33 IndraControl VAC 08 1 CDI Splitter Bosch Rexroth AG R911400465_Edition 01 ...
Page 39: ...Notes IndraControl VAC 08 1 CDI Splitter 33 33 ...