WARNING
Assembly destruction
If connected improperly, the assembly might be destroyed. For that reason,
avoid:
Polarity reversal with simultaneous short-circuit of the output lines
Polarity reversal with simultaneous connection of externally polarized suppres‐
sor diodes
Applying an external voltage > UB
The 0 V reference voltage of the connected loads must be returned to the 0 V
terminal of the IndraControl L10, i.e. a two-pin connection must be ensured.
Otherwise, there will be no reliable protection from GND breakage.
7.4
Interfaces
7.4.1
Ethernet Interface
Connector X7E can be used to connect the IndraControl L10 to an Ethernet
network.
The connection requirements defined for 100BaseT in IEEE 802.3 are appli‐
cable to Ethernet network connections.
RJ45 female connector, 8-pin
Type:
Ethernet 100BaseT
Cable length:
100 m max.
Cable type:
Shielded, twisted pair
Transmission rate:
10 or 100 Mbits/s
Fig.7-21:
Ethernet Interface
Two LEDs are integrated in the RJ45 female connector indicating the connec‐
tion status:
●
LED at the top (Link): Flashes green, if there is an Ethernet connection
●
LED at the bottom (Send): Flashes orange, if the data transmission occurs
via this line
Bosch Rexroth recommends the use of an STP cable of category 5. Cables for
this interface are listed in the order information.
7.4.2
Interface for the Compact Flash Card
The IndraControl L10 is equipped with a slot for a compact flash card. This slot
can be used to insert the memory card containing the firmware (card to be
Project Planning Manual | Rexroth IndraControl L10
Electric Drives
and Controls
| Bosch Rexroth AG
33/54